Operating principle
The heat pump transmits the energy contained in the
surrounding air into the dwelling to be heated.
The heat pump consists of four main elements, in which
a refrigerant fluid (R410A) circulates.
- In the evaporator (ref. 13,
The energy is taken from the surrounding air and is
transmitted to the refrigerant. Because it has a low
boiling point, it changes from the liquid state to the
vapour state, even in cold weather (down to -25°C
outdoor temperature).
- In the compressor (ref. 10,
The vaporised refrigerant brought to high pressure
and takes on more calories.
- In the condenser (ref. 14,
The energy in the refrigerant is transmitted to the
heating circuit. The refrigerant returns to liquid state.
- In the expansion valve (ref. 9,
The liquefied refrigerant is brought back to low pressure
and returns to its initial temperature and pressure.
The heat pump is equipped with a controller, which
controls the room temperature based on the outdoor
temperature measurement and governed by the
temperature control. The room thermostat (option)
provides a corrective action for the temperature control.
The hydraulic unit can be optionally fitted with an
electrical back-up system or boiler connection which
starts up in order to provide addtional heating during the
coldest periods.
- 10 -
1
1
12
12
6
6
14
14
9
9
15
7
7
13
13
10
10
2
2
3
11
3
11
figure 8 - Hydraulic unit components
figure 7, page
9) :
figure 7, page
9) :
figure 8, page
10) :
figure 7, page
9) :
Side view
Side view
• Regulation functions
- The heating circuit's initial temperature is controlled by
the temperature control.
- The power of the outdoor unit is modulated according
to flow heating temperature via the "Inverter"
compressor.
- Control of the electrical back-up heating (option).
- The daily timer program enables you to define
the periods for comfortable or reduced ambient
temperature.
- Summer/winter mode switchover is automatic.
- Control of the supplementary boiler* (options).
- The room thermostat (option)*: provides a corrective
action for the temperature control.
- Control of a second heating circuit*.
- Domestic hot water*: Heating time program, control of
the operation of the DHW circulation pump.
- Managing the cooling*.
- Control of swimming pool heating*.
* If the heat pump is equipped with optional equipment and the
associated kits.
• Protection functions
- Anti-legionella cycle for domestic hot water.
- Frost protection: Frost protection cuts in if the low-
temperature point of the heating circuit falls below 5°C.
Installation and operating manual "1765 - EN"
Legend :
Legend :
1 - Electric box.
1 - Electric box.
2 - Regulator / User interface.
2 - Regulator / User interface.
3 - Start/stop switch.
3 - Start/stop switch.
4 - Heating circulation pump.
4 - Heating circulation pump.
5 - Heating flow.
5 - Heating flow.
6 - Gas refrigeration connection.
6 - Gas refrigeration connection.
7 - Liquid refrigeration connection.
7 - Liquid refrigeration connection.
8 - Heating return.
8 - Heating return.
9 - Drain valve.
9 - Drain valve.
10 - Safety valve.
10 - Safety valve.
11 - Manometer.
11 - Manometer.
12 - Manual drainer.
12 - Manual drainer.
13 - Expansion vessel.
13 - Expansion vessel.
14 - Back-up resistance.
14 - Condenser.
15 - Condenser.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents