• This product should only be used for the purpose for which it was instructions • If the power cable is damaged, it must be replaced by the explicitly designed. Any other use is considered dangerous. CAME Cancelli manufacturer or the technical assistance service or by a person with a Automatici S.p.A.
For intensive or condominium use: max gate weight 300kg with max gate length 8,5 m. Reference standards The company CAME cancelli automatici is ISO 9001 quality certified; it has also obtained the ISO 14001 environmental safeguar- ding certification. CAME engineers and manufactures all of its products in Italy.
Description of parts 1) Top cover 2) Motor 3) Transformer 4) Trap door to access manual release of gearmotor 5) Securing plate 6) Securing bolt 7) Securing nut and washer 8) Protective cover for electronic card 9) ZN2 M3 electronic card 10)Card and battery rack support Dimensions (mm)
Tools and materials Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance with the current standards and regulations. The following figure illustrates the minimum equipment needed by the installer. Cable list and minimum thickness Length of cable Length of cable...
Page 6
Securing the plate and installing the assembly The following applications are only examples, as the space for installing the ratiomotor and accessories varies according to obstructions. It is thus up to the system installer to select the most suitable solution. - Dig a pit to the side of the gate (see measurements from diagram).
Page 7
Remove the form box (1), fi ll the pit around the cement block with soil (2) and unbolt the nuts and washers from the bolts (3). The securing plate must be clean, perfectly aligned and with the bolt threads completely on the surface. Insert the electric cables into the tubes until they exit about 400mm (4).
Page 8
- The following illustrations for the securing the rack, are just examples of applications. It is up to the installer to choose the best solution. Releasing the gearmotor (see paragraph on manual release). Rest the rack on the gearmotor pinion. Weld or secure the rack to the gate along its entire length.
Page 9
Adjusting the mechanical stops Adjusting the opening mechanical stops: - with the motor in release mode, fully open the gate. Activate the opening-microswitch, turning the white cam clockwise. Secure the cam by turning the screw. Opening-microswitch White cam Adjusting the closing endstop: - with the motor in release mode, fully close the gate.
Control board 6.1 General description Use 230V A.C. to power the electronic card using the L-N All connections are protected by quick-fuses – see table. terminals, at a max 50/60Hz frequency. F U S E TABL E Use 24V to power the command devices and accessories. To protect: Fuse: Careful! The accessories cannot exceed 37W of overall power.
6.3 Electrical connections Gearmotor, endstop and encoder Description of the standard electrical connections for left-hand installations White Orange Brown Green White Orange Green 24V (d.c.) motor Opening mi- Closing mi- with encoder croswitch croswitch Invert the gearmotor Modifications to the electri- (M-N) and (FA-FC) cal connections for right-hand endstop phases.
Page 12
Command and control devices Stop button (N.C. contact) - Gate stop button. Excludes automatic closing. For motion to resume, press the command button or the remote control button. Key selector and/or partial opening button (N.O. contact) - Partial gate opening for pedestrian access. Key selector and/or command button (N.O.
Page 13
DF with DFI con- nections monitor «Open while closing»(N.C.) contact card - input for EN 12978 compliant safety devices such as sensitive edges. During gate closing, opening the contact causes inversion of movement until gate is fully open; if not used, short circuit contact 2-C7.
Page 14
Settings - «PAR.OP.» Sets the gate’s partial opening. By pushing the partial opening button connected at 2-3P, the gate opens depending on the length of the gate. - «SLOW S.» Sets the amperometric sensitivity that controls the force generated by the motor during slow down; if the force exceed the set level, the system intervenes by inverting the direction of motion.
Programmation to save gate-run and decelerations adjustments Do the adjustment by making the operator execute a complete opening/closing manoeuvre The control board automatically registers the gate-run adjustments with opening and closing decelerations. To save the adjustment, position dip 6 in ON and press PROG button until the signalling led stays on. Re-position the dip in OFF PROG LED acceso...
Page 16
Connecting two coupled gearmotors having a single control With two coupled gearmotors, you can command only the opening (by button and/or radio control): the gate will close only in automatic closing mode. • Coordinate the direction of travel of the two gearmotors , by modifying the motor's rotation (invert the cables on terminals FA-FC and M-N).
Important safety instructions This product must only be employed for its originally intended use. Any other use is wrong and potentially dangerous. The manufacturer cannot be held liable for any damages resulting from wrongful, erroneous or negligent uses. Avoid working close to the hinges or other moving mechanical parts. Stay out of the opening/closing arc when operator is in motion. Do not exercise force against the motion of the operator as this could result in potentially dangerous situations.Do not allow children to play or loiter within the opening/closing arc of the operator.
Periodic maintenance log for end-user (every 6 moths) Signature Date Notes Trouble shooting MALFUNCTIONS POSSIBLE CAUSES CHECK AND REMEDIES The gate will not • There is no power • Check that the power is up open nor close • The release door is open •...
CAME CANCELLI AUTOMATICI S.p.A. employs a UNI EN ISO 14001 certified and compliant environmental protection system at its plants, to ensure that environmental safeguarding. We ask you to keep protecting the environment, as CAME deems it to be one of the fundamental points of its market operations strategies, by simply following these brief guidelines when disposing: DISPOSING THE PACKING MATERIALS The packing components (cardboard, plastic, etc.) are solid urban waste and may be disposed of without any particular difficulty, by simply...
Page 20
HR • Za sve dodatne informacije o poduzeću, proizvodima i tehničkoj podršci: UK • Для отримання будь-якої іншої інформації про компанію, продукцію та технічну підтримку: www. came.com www. came.com CAME Cancelli Automatici S.p.a. CAME Cancelli Automatici S.p.a. Via Martiri Della Libertà, 15 31030 Dosson Di Casier...