FLEXIDOME IP starlight
7000 VR
Connect the yellow/green wire of the camera to the system
earth of the installation to ensure correct safety and EMC/RFI
protection.
5.3.3

Network (and PoE power)

Connect the camera to a 10/100 Base-T network:
Notice!
Use only PoE approved devices.
Power-over-Ethernet can be connected at the same time as a
12 VDC power supply. If auxiliary power (12 VDC) and PoE is
applied simultaneously, the camera selects PoE and shuts off
the auxiliary input.
5.3.4

Auxiliary power

Connect a SELV-LPS or a SELV Class 2 power supply with a
rated supply voltage of 12 VDC as follows:
Caution!
Use only a +12 VDC power supply as an auxiliary power source.
!
The auxiliary power supply unit must be isolated from earth.
5.3.5

Alarm

Use the stranded and solid wires with maximum diameter AWG
22-28; only cut back 5 mm (0.2 in) of insulation.
Bosch Security Systems
Use STP Category 5e cable with RJ45 connectors (the
camera network socket is Auto MDIX compliant).
Power is supplied to the camera via the Ethernet cable
compliant with the Power-over-Ethernet standard.
Cut back 7 mm (0.28 in) of insulation.
Connect the power wires (red+ , brown-) to the external
power supply.
Installation | en
2016.06 | v1.0 | AM18-Q0710