Hisense AVW-38UCSC Installation & Maintenance Manual page 37

Inverter-driven multi-split air conditioner, heat pump
Table of Contents

Advertisement

Model(s):AVW-48UCSC
Outdoor side heat exchanger of air conditioner/heat pump:air
Indoor side heat exchanger of air conditioner/heat pump:air
Type: compressor driven vapour compression
Driver of compressor:electric motor
Indication if the heater is equipped with a supplementary heater:no
Parameters shall be declared for the average heating season
Item
Rated cooling capacity
Declared capacity (*) for cooling, at indoor temperature 27(19) °
C and outdoor temperature Tj
Tj = 35
Tj = 30
Tj = 25
Tj = 20
co-efficient for air
conditioners(*)
off mode
thermostat-off
mode(cooling)
Rated heating capacity
Declared heating capacity for part load at indoor temperature 20 °C
and outdoor temperature Tj
Tj = – 7
Tj = 2
Tj = 7
Tj = 12
Tj = bivalent temperature
Tj = operating limit
Bivalent temperature
heating/Average
heating/Warmer
heating/Colder
Degradation co-efficient
heat pumps(**)
Power consumption in modes other than 'active mode'
off mode
thermostat-off
mode(heating)
crankcase heater mode
Capacity control
Sound power level ,
indoor/outdoor measured
Global warming potential
Note
Contact details
Technical parameters
Symbol
Value
P
14.0
rated,c
Pdc
13.2
Pdc
9.8
Pdc
6.3
Pdc
2.9
Cdc
0.25
Power consumption in modes other than 'active mode'
P
0.04
OFF
P
0
TO
P
16.0
rated,h
Pdh
10.0
Pdh
5.8
Pdh
3.8
Pdh
1.7
Pdh
10.0
Pdh
9.0
Tbiv
-7
Tbiv
Tbiv
Cdc
0.25
P
0.04
OFF
P
0.05
TO
P
0.01
CK
variable
LWA
-/70
GWP
2088
kgCO
The above performance data is obtained on the basis of the performance of this outdoor
unit, with a 100%-combination of ceiling ducted type indoor units.
Qingdao Hisense Hitachi Air-conditioning Systems Co., Ltd.
218, Qianwangang Road, Economic and Technological Development Zone, Qingdao, P.R. China
Unit
Item
cooling
Seasonal space cooling
kW
energy efficiency
Declared energy efficiency ratio (*), at indoor temperature
27(19) °C and outdoor temperature Tj
kW
Tj = 35
kW
Tj = 30
kW
Tj = 25
kW
Tj = 20
kW
crankcase heater mode
kW
standby mode
heating
Seasonal space heating
kW
energy efficiency
Declared coefficient of performance (*)/Average season, at indoor
temperature 20 °C and outdoor temperature Tj
kW
Tj = – 7
kW
Tj = 2
kW
Tj = 7
kW
Tj = 12
kW
Tj = bivalent temperature
kW
Tj = operating limit
Operating limit temperature
heating/Average
heating/Warmer
heating/Colder
kW
Back-up heating capacity (*)
kW
Type of energy input
kW
standby mode
Other items
air flow rate, outdoor
measured
dB(A)
eq.
2
29
Symbol
Value
η
363.7
s,c
EERd
3.49
EERd
6.71
EERd
10.92
EERd
23.17
P
0
CK
P
0.04
SB
η
179.1
s,h
COPd
2.58
COPd
4.17
COPd
7.67
COPd
7.27
COPd
2.58
COPd
2.46
Tol
-10
Tol
Tol
elbu
0
P
0.04
SB
6300
m3/h
unit
%
kW
kW
%
kW
kW

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avw-48ucscAvw-54ucsc

Table of Contents