However, if a power failure lasts for long, or the power voltage decreases, TP04P will
stop running, and all outputs will be off. After the power returns to the normal status,
TP04P will automatically resume the operation. (Users have to note that TP04P is
equipped with latched auxiliary relays and registers when they write a program.)
Safety Wiring
Since TP04P is only compatible with DC power supply, Delta's power supply modules
(DVPPS01/DVPPS02) are suitable for it. İt is suggested that you shoudl install a
protection circuit at the power supply terminal to protect DVPPS01 or DVPPS02. See
the figure below.
AC power supply:100 ~ 240VAC, 50/60Hz
Emergency stop: The emergency stop button can be used to cut off the power when an
emergency occurs.
Power indicator
Power supply circuit protection fuse (2A)
DC power supply output: 24VDC, 500mA
Digital I/O module
Input Point Wiring
There are 2 types of DC inputs, SINK and SOURCE. (See the figures below)
SINK Mode
+24V
0V
DC Power Supply
Relay (R) output circuit wiring (Sink)
S/S
X0
X1
X2
Sink mode
Figure 8
Breaker
AC power supply load
DVPPS01/DVPPS02
DVP series PLC (main processing unit)
SOURCE Mode
+24V
0V
DC Power Supply
- 6 -
Figur e 7
S/S
X0
X1
X2
Source mode
Figure 9
Figure 10