4.19 TRIGger Group

4.19 TRIGger Group
The commands in this group deal with the trigger.
You can make the same settings and inquiries as when the TRIGGER key on the front panel is used.
:
: TRIGger
:TRIGger?
Function
Queries all settings related to the trigger.
Syntax
:TRIGger?
Example :TRIGGER? -> :TRIGGER:START 1
;SOURCE OFF;SAMPLING OFF
:TRIGger:MANual
Function
Executes manual trigger input.
Syntax
:TRIGger:MANual
Example :TRIGGER:MANUAL
Description The sequence trigger function is an option.
4-66
;
STARt
<Space>
SOURce
<Space>
SAMPLing
<Space>
MANual
<Boolean>
?
OFF
OUT1
OUT2
OUT3
OUT4
EXTernal
?
OFF
OUT1
OUT2
OUT3
OUT4
EXTernal
?
?
:TRIGger:SAMPLing
Function
Sets the output terminal set that is output to
Sampling Clock Source or queries the current
setting.
Syntax
:TRIGger:SAMPLing {OFF|OUT1|OUT2|
OUT3|OUT4|EXTernal}
:TRIGger:SAMPLing?
Example :TRIGGER:SAMPLING OFF
:TRIGGER:SAMPLING? ->
:TRIGGER:SAMPLING OFF
Description The sequence trigger function is an option.