S = Default, L = Loco address, S = Switch address, LS = Loco and switch address usable
CV
Description
1
Lokadresse
7
Software version
7
3 ranges available
8
Manufacturer ID
7+8
Reg8 = CV-Address
Reg7 = CV-Value
9
SDF-House time min in minute
10
SDF- House time max in minute
12
Random generator
13
Automatic protocoll detection
14
Locomotive/switch control
15
Programming lock (key)
16
Programming lock (lock)
17
SDF time for function
18
Switch address calculation
19
Restore last position after restart
or voltage drop
16

CV-Table

S
L/S
Range
3
L
1 – 127
Decoder reset functions
11
16
33
160
Register programming mode
S
3
1 – 255
15
S
1 – 255
0
W
0 – 255
LS
0
0/1
LS
1
0/1
75
S
0 – 255
75
S
0 – 255
S
10
0 – 255
0
S
0/1
LS
0
0 – 255
Note
only if CV14 = 0
read only (10 = 1.0)
basic settings (CV 1,11-13,17-19)
programming lock (CV 15/16)
function- & Switch outputs (CV 20-49)
read only
CV 7/8 don't changes his real value
CV 8 write first with cv-number, then CV 7
write with value or read
(e.g.: CV 49 should have 3)
➔ CV 8 = 49, CV 7 = 3 writing
minimal time for reload rate
maximum time for reload rate
Add value to the CV for function
0 = deactive
+1 = A1, +2 = A2, +4 = A3, +8 = A4, +16 = A5,
+32 = A6
0 = automatic detection
1 = only DCC (recommended for multi-
protocol command stations)
0 = locomotive control
1 = turnout control
to lock only change this value
changes in CV 16 will change CV 15
time base (10 ms / value)
0 = Switch adress like norm
1 = Switch adress like Roco, Fleischmann
Add value to the CV for function
0 = deactive
+1 = A1, +2 = A2, +4 = A3, +8 = A4, +16 = A5,
+32 = A6
RD6