ABB PVI-3.0-TL-OUTD-S-US Product Manual page 57

Solar inverters
Table of Contents

Advertisement

Display Message
Causes
E029
Error in the internal measurement
Error Meas Z
of the insulation resistance of the
ZGrid
Measures
PV array compared to ground
Fault
(imposed by regulations) to have
a measurement redundancy (2
measurements on the same pa-
rameter carried out by two differ-
ent circuits).
E030
Error in the internal measurement
Error Meas Ileak
(carried out when the inverter is
ILeak
Measures
connected to the grid) of the leak-
Fault
age current of the DC side (PV
array) compared to ground (im-
posed by regulations) to have
a measurement redundancy (2
measurements on the same pa-
rameter carried out by two differ-
ent circuits).
E031
Measurement of the internal volt-
Error Read V
age at the ends of the output relay
Wrong V Measure
out of range. There is too great a
difference in voltage between the
input and the output of the output
relay that can be caused by grid
voltage instability.
E032
Measurement of the output volt-
Error Read I
age unbalance (carried out be-
Wrong I Measure
tween the three phases) out of
range (only in three-phase mod-
els).
E033
Alarm is triggered when internal
UTH
temperature is below low temper-
Under Temperature
ature threshold.
Depending where the inverter
is located, ambient temperature
can reach values below UT lim-
its. In case in which ambient tem-
perature is above that UTH limits,
a failure of the temp sensing cir-
cuitry is occurred.
E034
Error inside the inverter
Interlock fail
IGBT not ready
Solution
Error inside the inverter that cannot be checked
externally. The error occurs if the internal measure-
ment is carried out before connection to the grid) If
the problem is persistent (even after switching the
inverter off and then on again), contact customer
service.
This is an error inside the inverter that cannot be
checked externally. If the problem is persistent
(even after switching the inverter off and then on
again), contact customer service.
Check the grid conditions for instabilities caused by
switch of heavy loads or reactive loads (like motors,
welding machines etc.). If the problem appears re-
peatedly, contact customer service.
This is an error inside the inverter that cannot be
checked externally. If the problem appears repeat-
edly contact customer service.
Wait for the temperatures to which the inverter is
exposed to return within operating range. If the
problem persists, contact customer service. Re-
member to wait for the time necessary to allow the
inverter to warm up.
Error inside the inverter that cannot be checked ex-
ternally. If the problem persists (after switching the
inverter off and then on again), contact customer
service.
- 57 -
5 - Troubleshooting