5.
Malicious operation of solenoid valve protection
In 10 seconds, if the solenoid valve is operated continuously for 10 times, it is judged as malicious
operation, and the system will automatically protect it.(In the protection state, press the remote control
host to respond normally, but the lock solenoid valve does not respond (does not act). After 15 seconds,
it will automatically exit the solenoid valve protection and return to normal.
6.
Alarm pause
When the vehicle is in the vibration alarm state: the alarm can be suspended by short pressing the
fortification key, release key or mute key, and the original fortification state remains unchanged. (Press
any key to remove the alarm without changing the alarm state)
7.
Alarm mode
trigger
Alert state
sound and light
warning state
silent alert state
8.
LED status
state
LED status
Fortification
Flash 4 times every 1.5 seconds, and turn off after 5 seconds
relieve
Flash once every 1 second and turn off after 5 seconds
Normally on for 5 seconds and then off
Main switch ON
alarm
Flashing with alarm
9.
PKE UNLOCK
On alert: When the main switch is turned from off to lock,Press the PKE wake-up key of the lock handle
(or when the body vibration is detected) to wake up PKE, When the remote control is within 1m-3m, the
lock is unlocked and the alert is released.
Press the PKE wake-up key of the lock handle (or when body vibration is detected) at off gear. If ACC is
not opened within 20 seconds after PKE unlocking, it will automatically return to the original anti-theft
alert state (sound light alert or silent alert).
Press the PKE wake-up key of the lock handle in lock gear (or detect the vibration of the car body). If the
PKE does not exit the lock gear within 15 seconds after unlocking, it will automatically return to the
original anti-theft alert state (sound light alert or silent alert)。
After lock is pressed and PKE wake-up key (or when body vibration is detected), PKE will turn to off after
unlocking, and lock automatically for 15 seconds, enter silent warning, and press release key twice in 2
seconds in 2 seconds to completely release.
10 :IMMO Induction unlocking
On alert: When the main switch is turned from off to lock, After pressing the PKE wake-up key of the
lock handle, the back of the remote control will be within 1cm of the sensing area of the IMMO antenna
within 10 seconds to automatically unlock. IMMO. If the sensor is still in lock or off after unlocking, it will
automatically return to the original anti-theft alert state(sound light alert or silent alert)
(When the remote control battery is too low to use, you can use this function to unlock)
1 1 :Malicious operation of PKE protection
After continuously pressing the PKE wake-up key for 10 times within 15 seconds (the 10th time of forced
locking and entering,the silent alert), it is determined as malicious operation, and the system
automatically enters the PKE protection state for 15seconds. In the protection state, press the remote
control host to respond normally, but the lock operation and PKE function are invalid. After 15 seconds, it
will automatically exit the protection and return to normal.
First vibration trigger
alarm three times
No alarm
Vibrate again in 15 seconds
Acousto-optic alarm for 15 seconds
(after 8 consecutive cycles, enter the
sound and light warning state)
No alarm