Tools And Equipment Required - Garnet SeeLevel 710-JS Manual

Holding tank monitor
Hide thumbs Also See for SeeLevel 710-JS:
Table of Contents

Advertisement

INSTALLATION INFORMATION
The installation for the complete system consists of mounting the display
inside the RV, cutting and mounting the senders to the sides of the tanks,
connecting the wiring, and programming the display.
This manual provides information on how to install the SeeLeveL 710-JS,
710-ES, and 710-SS senders.
W
NOTE: The new 710-AR, 710-ES2 can be combined with old sender models 710-ES,
710-JS, 710-SS.
Before senders are installed the display should be installed first.
Refer to the Display Installation Guide and User Manual for the model
you've purchased for all installation and connection details. Manuals can
be found at our online Resource Library from our website at:
http://https://www.garnetinstruments.com/holding-tanks-resource-library/

Tools and equipment required:

Wire cutters/stripper
Wire crimper
Scissors or hole punch
Acetone/rubbing alcohol
Duct tape or tie-wraps for securing wires
Non aggressive tape (painters, masking)
Electrical tape
Butt connectors
SeeLeveL Sender Installation Manual 710-JS / 710-ES / 710-SS
DETERMINE BEST CONFIGURATION & LOCATION
Sender Placement
The senders will need to have a flat area on the side of the tank large
enough so the whole width of the sender is in contact with the side of the
tank.
Make sure that any metal is at least 1" away from either side, top and
bottom of the sender, and at least 2" away from the face of the sender.
Some tanks may have
irregular shapes. DO NOT
wrap the corners over the top
or bottom of the tank.
See placement examples to
the right.
W
CAUTION: Bending the
sender sharply will damage the
circuit on the sender.
Sender Configuration
To determine which sender configuration you need, measure the height of
your tanks, then find out the measurable space (see following page). The
measurable space is the "ideal" position of the sender on the tank. This
will determine what length the senders should be. If a sender is too long,
it will need to be cut. The following table has recommended senders and
configurations for various tank heights.
Tank
Height
Best Resolution
5" - 5.5"
5.5" - 7"
7" - 13"
13" - 17"
710-ES stacked
17" - 25"
710-ES stacked
25" - 33"
710-SS stacked
W
CAUTION: 710-JS Senders cannot be double-stacked.
DO NOT mix sender types when stacking senders.
Sender Options
Other Possible
710-JS single
-
710-JS single
710-ES single
710-ES single
710-SS single
710-SS single
710-SS stacked
-
Page 2

Advertisement

Table of Contents
loading

Table of Contents