44

Thermostat Installation (Optional)

DO NOT CONNECT 120 VAC OR 24V TO THE THERMOSTAT CIRCUIT OF THIS HEATER
(DO NOT USE A HOUSEHOLD THERMOSTAT USED FOR A WALL-BOARD OR OTHER
ELECTRICAL HEATER). USE A LOW VOLTAGE COMPATIBLE THERMOSTAT.
Wired or wireless thermostats may be attached to this appliance. Open the left side access panel and
locate the wires labeled "TSTAT". Route the thermostat wires to this location and attach them to these
wires (orientation does not matter). Make sure the wires do not contact hot or moving components. See
the instructions included with the thermostat for further details.

Outside Air Kit

See the instructions included with the outside air kit for full details.
Back of AGP Pellet
Stove
Cut a minimum 2" diameter hole in the wall
© Travis Industries
Optional Equipment
Seal the area around the
tube to prevent air from
entering through the wall.
3-1/2"
Cover Plate &
1-1/4" screws
5-3/4"
(use 2" dia. hole saw).
1-3/4" Diameter Flex Duct
4/11/22- 1566
Select a location between framing
members for the outside air hole.
Hood with Screen
3/8" Screws
1-1/4"
Screws
AGP Stove

Advertisement