Condensing wall mounted gas boiler combi and heating only (92 pages)
Summary of Contents for ECR International 75F
Page 1
APPLICATION GUIDE FOR USE WITH FLOOR STANDING HEATING ONLY - 75F, 100F, 125F, 165F & COMBI - 115F, 150F, 205F This manual has been prepared for use with the appropriate Installation, Operation and Maintenance Manual. Manufactured by: ECR International Inc.
75F, 100F, 125F W/Indirect Zone circulators, DHW tank w/Sensor - Wiring Dia....11 75F, 100F, 125F w/Indirect Zone circulators & DHW Tank w/t-stat - WIRING Dia....12 75F, 100F, 125F with Zone Valves & DHW Tank - PIPING Diagram ........13 75F, 100F, 125F with Zone Valves, DHW Tank W/Sensor - Wiring Dia.
IMPORTANT SAFETY INFORMATION 1. 1. Become familiar with symbols identifying Become familiar with symbols identifying 3. Installation shall conform to requirements of potential hazards. potential hazards. authority having jurisdiction or in absence of such requirements: • United States • National Fuel Gas Code, ANSI Z223.1/NFPA 54. This is the safety alert symbol.
GENERAL INFORMATION - HYDRONIC PIPING FOR YOUR SAFETY READ BEFORE OPERATING WARNING Burn and scald hazard! Manufacturer requires installation of field supplied anti-scald valve. DANGER Failure to follow these instructions could result in death or serious injury. General Information: Piping installation, materials, and joining methods shall conform to requirements of authority having jurisdiction or in absence of such requirements: •...
Page 7
GENERAL INFORMATION - HYDRONIC PIPING Use of Indirect Water Heater (DHW) Heating Water 1st Degree Burn 2nd and 3rd Degree Burn Only Boiler: Temperature Exposure Time For Exposure Time For An Setting An Adult Adult 120° F 1 minute 5 minutes Note Sensors supplied with this boiler are 130°...
GENERAL INFORMATION - WIRING Electrical Wiring Information: DO NOT use 120 V thermostat Note All field wiring shall conform to the authority having terminals (M1- #1 and #2). jurisdiction or, in the absence of such requirements to: • USA: National Electrical Code, ANSI/NFPA 70, •...
EXTERNAL BUFFER TANK - PIPING DIAGRAM Buffer Tank Piping When installing low mass systems, additional water mass may be required to avoid short cycling by the boiler. In these applications it is recommended that a buffer tank be installed. Buffer Tank on Central Heat Circuit Using Internal Boiler Circulator Note: •...
Page 25
EXTERNAL BUFFER TANK - PIPING DIAGRAM Buffer Tank On Central Heat Circuit With Primary Pump and Supplied Manifold ZONE PUMPS OR ZONE VALVES Optional Indirect Tank CH System Pump PURGE VALVE MAGNETIC DIRT H2O Stainless SEPARATOR Steel Buffer Tank NOTE : Acceptable primary pump locations: Either 1 or 2.
EXTERNAL BUFFER TANK - WIRING DIAGRAM Buffer Tank Pump Wiring Controlling A Primary Pump On A Combi Boiler With Zone Valves, No Indirect Tank PN 240012875 REV. D [03/15/2022]...
Page 27
EXTERNAL BUFFER TANK - WIRING DIAGRAM Buffer Tank Pump Wiring Controlling A Primary Pump On A Combi Boiler With Zone Pumps, Argo ARM 4P Zone Control and A822-II PN 240012875 REV. D [03/15/2022]...
Page 28
EXTERNAL BUFFER TANK - WIRING DIAGRAM Buffer Tank Pump Wiring Controlling A Primary Pump On A Combi Boiler With Zone Valves and Indirect Tank With Priority, Argo UZ3 and AR822-II Zone Controls ZONE VALVES ZONE VANNES DE ZONE THERMOSTATS 4 Wire Valve Domestic Hot Water Tank Buffer Tank...
OPTIONAL EQUIPMENT Optional Equipment IMPORTANT: Sensors supplied with this boiler are proprietary to the manufacturer. Use of alternate market sensors WILL diminish boiler performanc Outdoor Air Sensor, if used. 1k Ω A. Boiler automatically recognizes sensor when used. B. See Chart 1 for sensor data. Sensor part number BD710487302V C.
ACCESSORIES 1. 1K Ohm (1k Ω) Outdoor Temperature 1k Ω Sensor Kit - BD710487302V • Use the Outdoor Sensor (OAS) Kit with Heating Only or Combi Boilers. • Wire Control to boiler M2 terminal strip, terminals 4 and 5 as shown. •...
ACCESSORIES 2. 10k Ω Indirect Storage Tank Sensor Kit Parameter PO3 for Heating Only boiler, with no Note indirect tank remains Factory Set at 08. No change Heating Only boiler can be electrically connected to is required. Indirect Storage Tank. If adding an Indirect Tank with a sensor to Diagram of electrical connection of external indirect Heating Only Boiler - change PO3 parameter...
APPLICATION TABLE - INDIRECT HOT WATER TANK PERFORMANCE CHART HEATING ONLY BOILERS 75, 100, 125, 165 Boiler Output Boiler Pressure Continuous Max. First Needed For Water Flow Drop Rating Hour Rating Maximum Through Through Coil Performance Coil Model Gal/Hr. @ Gal/Hr @ (BTU/Hr) Gal/Min...
LOW WATER CUTOFF • Locate LWCO sensing device in the supply Low Water Cut Off - Heating Only and Combi Boilers piping, above the minimum height of boiler. See Figure page 42, Piping Diagram. These guidelines are supplied when necessary to install an additional Low Water Cut Off (LWCO), for sensing a •...
LOW WATER CUTOFF PIPING DIAGRAM - LWCO LOCATION Arrange piping to prevent water Note dripping onto boiler. Illustrations are meant to show system piping concept only. Installer Note is responsible for all equipment and detailing required by authority having Air Vent jurisdiction.
ERROR CODE TABLE Initial Fault Finding Checks Note: When instructed press and hold “RESET” for between 1-3 seconds to reset the boiler. Check gas, water and electrical supplies are available at the boiler Table of Error Codes Electrical supply = 120V ~60 HZ Gas Valve Connection Cable The preferred minimum gas pressure is 3.5”...
FAULT SOLUTION SECTIONS Fault Finding Solutions Sections Power supply 120V Main terminals L and N Check electrical supply Connection OK at connector x1 0 Integrity of the fuse Replace fuse Main or Display Display PCB fault illuminated PCB - X1 0 connector Check wiring Mains terminals L &...
Page 49
FAULT SOLUTION SECTIONS PN 240012875 REV. D [03/15/2022]...
Page 50
FAULT SOLUTION SECTIONS Overheat thermostat operated or Check for and correct any system faulty. faults (water circulation). Allow to cool. Continuity �I across thermostat terminals � Replace safety thermostat '---------------' more than 1.5 ohm Is E11 O is still flashing Check Flow, Return, Replace PCB sensors.
Page 51
FAULT SOLUTION SECTIONS PCB connector x22 Hall With water running effect sensor terminals. Is main water filter and through DHW circuit, Check the voltage is Check DHW NTC assembly clean and measure red and white Replace PCB approximately 5 VDC senor for proper OHM rotor free to move? wire for 2.8 VDC for...