APPLICATION GUIDE FOR USE WITH HEATING ONLY - 100, 125, 165 & COMBI - 115, 150, 205 This manual has been prepared for use with the appropriate Installation, Operation and Maintenance Manual. Manufactured by: ECR International Inc. 2201 Dwyer Avenue, Utica, NY 13501 Tel.
100, 125 W/Indirect Zone Circulators, DHW Tank W/Sensor - Wiring Diagram ....... 11 100, 125 W/Indirect Zone Circulators & DHW Tank W/T-Stat - Wiring Diagram ......12 100, 125 With Zone Valves & DHW Tank - Piping Diagram ............13 100, 125 With Zone Valves, DHW Tank W/Sensor - Wiring Diagram ..........
IMPORTANT SAFETY INFORMATION 3. Installation shall conform to requirements of 1. 1. Become familiar with symbols identifying Become familiar with symbols identifying authority having jurisdiction or in absence of such potential hazards. potential hazards. requirements: • United States • National Fuel Gas Code, ANSI Z223.1/NFPA 54. This is the safety alert symbol.
GENERAL INFORMATION - HYDRONIC PIPING FOR YOUR SAFETY READ BEFORE OPERATING WARNING Burn and scald hazard! Manufacturer requires installation of field supplied anti-scald valve. DANGER Failure to follow these instructions could result in death or serious injury. General Information: Piping installation, materials, and joining methods shall conform to requirements of authority having jurisdiction or in absence of such requirements: •...
Page 7
GENERAL INFORMATION - HYDRONIC PIPING Water 1st Degree Burn 2nd and 3rd Degree Burn Use of Indirect Water Heater (DHW) Heating Temperature Exposure Time For Exposure Time For An Setting An Adult Adult Only Boiler: 120° F 1 minute 5 minutes 130°...
GENERAL INFORMATION - WIRING Electrical Wiring Information: DO NOT use 120 V thermostat Note terminals (M1- #1 and #2). All field wiring shall conform to the authority having jurisdiction or, in the absence of such requirements to: • USA: National Electrical Code, ANSI/NFPA 70, Provided Wiring and Piping •...
EXTERNAL BUFFER TANK - PIPING DIAGRAM Buffer Tank Piping When installing low mass systems, additional water mass may be required to avoid short cycling by the boiler. In these applications it is recommended that a buffer tank be installed. Buffer Tank on Central Heat Circuit Using Internal Boiler Circulator Note: •...
Page 25
EXTERNAL BUFFER TANK - PIPING DIAGRAM Buffer Tank On Central Heat Circuit With Primary Pump and Supplied Manifold NOTE : Acceptable primary pump locations: Either 1 or 2. For pump wiring see diagrams on pages 26-29. PN 240011430 REV. P [09/15/2021]...
EXTERNAL BUFFER TANK - WIRING DIAGRAM Buffer Tank Pump Wiring Controlling A Primary Pump On A Combi Boiler With Zone Valves, No Indirect Tank PN 240011430 REV. P [09/15/2021]...
Page 27
EXTERNAL BUFFER TANK - WIRING DIAGRAM Buffer Tank Pump Wiring Controlling A Primary Pump On A Combi Boiler With Zone Pumps, Argo ARM 4P Zone Control and A822-II PN 240011430 REV. P [09/15/2021]...
Page 28
EXTERNAL BUFFER TANK - WIRING DIAGRAM Buffer Tank Pump Wiring Controlling A Primary Pump On A Combi Boiler With Zone Valves and Indirect Tank With Priority Argo UZ3 and AR22II Zone Controls ZONE VALVES ZONE VANNES DE ZONE THERMOSTATS 4 Wire Valve Domestic Hot Water Tank Buffer Tank...
C. Locate outdoor sensor to protect against wind and direct sunlight. Mounting instructions provided with sensor. D. Maximum wire length is 100 ft (30m) for 22 ga. wire, or 150 ft (45m) for 18 ga. wire. E. Connect wires to M2 OUTDOOR SENSOR terminals 4 & 5. Wires are interchangeable. See Accessories.
ACCESSORIES 1. 1K Ohm (1K Ω) Outdoor Temperature 1k Ω Sensor Kit - BD710487302V • Use the Outdoor Sensor (OAS) Kit with Heating Only or Combi Boilers. • Wire Control to boiler M2 terminal strip, terminals 4 and 5 as shown. •...
Page 31
10k Ω Indirect DHW Tank Indirect DHW Tank Sensor Wiring End Switch Wiring (100 & 125 MODELS) (100,125 & 165 Management of 0-10V Input MODELS) To activate the 0-10v function parameter 82 must be set to 3. There must be at or above 3 V DC present for the control to recognize a call for heat.
APPLICATION TABLE - INDIRECT HOT WATER TANK PERFORMANCE CHART HEATING ONLY BOILERS 100, 125, 165 BOILER OUTPUT NEEDED FOR MAXIMUM PERFORMANCE Notes: 176 °F Boiler Supply Water Temperature, AHRI Conditions -50 °F Inlet Water @ 240 GPH Flow Rate. PN 240011430 REV. P [09/15/2021]...
LOW WATER CUTOFF • Locate LWCO sensing device in the supply Low Water Cut Off - Heating Only and Combi Boilers piping, above the minimum height of boiler. See Figure page 42, Piping Diagram. These guidelines are supplied when necessary to install an additional Low Water Cut Off (LWCO), for sensing a •...
LOW WATER CUTOFF Piping Diagram - LWCO Location Arrange piping to prevent water dripping onto boiler. Note Illustrations are meant to show system piping concept only. Installer Note is responsible for all equipment and detailing required by authority having jurisdiction. Air Vent Position LWCO Above Top of Boiler...
ERROR CODE TABLE Initial Fault Finding Checks Note: When instructed press and hold “RESET” for between 1-3 seconds to reset the boiler. Check gas, water and electrical supplies are available at the boiler Table of Error Codes Electrical supply = 120V ~60 HZ Gas Valve Connection Cable The preferred minimum gas pressure is 3.5”...
FAULT SOLUTION SECTIONS Fault Finding Solutions Sections Power supply 120V Main terminals L and N Check electrical supply Connection OK at connector x1 0 Integrity of the fuse Replace fuse Main or Display Display PCB fault illuminated PCB - X1 0 connector Check wiring Mains terminals L &...
Page 48
FAULT SOLUTION SECTIONS PN 240011430 REV. P [09/15/2021]...
Page 49
FAULT SOLUTION SECTIONS Overheat thermostat operated or Check for and correct any system faulty. faults (water circulation). Allow to cool. Continuity �I across thermostat terminals � Replace safety thermostat '---------------' more than 1.5 ohm Is E11 O is still flashing Check Flow, Return, Replace PCB sensors.
Page 50
FAULT SOLUTION SECTIONS PCB connector x22 Hall With water running effect sensor terminals. Is main water filter and through DHW circuit, Check the voltage is Check DHW NTC assembly clean and measure red and white Replace PCB approximately 5 VDC senor for proper OHM rotor free to move? wire for 2.8 VDC for...