Notes; Receiving The Product; Inspecting The Product; Installation Requirements - Grundfos UNILIFT AP35B Installation And Operating Instructions Manual

Table of Contents

Advertisement

1.2 Notes

The symbols and notes below may appear in
Grundfos installation and operating instructions,
safety instructions and service instructions.
Observe these instructions for explosion-
proof products.
A blue or grey circle with a white graphical
symbol indicates that an action must be
taken.
A red or grey circle with a diagonal bar,
possibly with a black graphical symbol, in-
dicates that an action must not be taken or
must be stopped.
If these instructions are not observed, it
may result in malfunction or damage to the
equipment.
Tips and advice that make the work easier.

2. Receiving the product

WARNING
Falling objects
Death or serious personal injury
Keep the product in a stable position
during unpacking.
Wear personal protective equipment.

2.1 Inspecting the product

Check that the product received is in accordance with
the order.
Check that the voltage and frequency of the product
match voltage and frequency of the installation site.
6

3. Installation requirements

CAUTION
Toxic material
Minor or moderate personal injury
The product will be classified as conta-
minated if it has been used for a liquid
which is injurious to health or toxic.
Wear personal protective equipment.
Installation must be carried out by special-
ly trained persons and according to local
regulations.
According to EN 60335-2-41/A2:2010, this
product with 5 m of mains cable must only
be used for indoor applications.

3.1 Location

Always have at least 3 m free cable above
liquid level. This limits the installation
depth to 7 m for pumps with 10 m cable
and to 2 m for pumps with 5 m cable.
3.1.1 Minimum space
The pit, basin or tank must be sized according to the
relation between the water flow to the pit, basin or
tank and the pump performance.
When the pump is installed in a permanent
installation with a float switch, the minimum
dimensions of the pit, basin or tank must be as shown
in fig. Minimum pit dimensions when the float switch
is set to the minimum free cable length to ensure free
movability of the float switch. The float switch is set to
the minimum free cable length. See section Adjusting
the float switch cable length.
550 mm
Minimum pit dimensions when the float switch is set
to the minimum free cable length
Related information
3.2.7 Adjusting the float switch cable length