11.6 Other timings
See HOST INTERFACE section for timings which are not shown here.
POWER ON TIMINGS
From power on to BSY=1
From Power on to BSY=0, DRDY=1
SOFT RESET TIMINGS
From soft reset assertion (SRST=1) to BSY=1
From soft reset negation (SRST=0) to drive ready (BSY=0, DRDY=1)
HARD RESET TIMINGS
From hard reset assertion to BSY=1
From hard reset negation to drive ready (BSY=0, DRDY=1)
DATA IN COMMANDS
From writing to command register to BSY=1
From BSY=1 to BSY=0, DRQ=1, INTRQ set (When the drive is in idle mode)
From BSY=1 to BSY=0, DRQ=1, INTRQ set (When the drive is in standby mode)
Drive Busy during data transfer
DATA OUT COMMANDS
From writing to command register to BSY=1
From BSY=1 to BSY=0, DRQ=1
Drive Busy during data transfer
From BSY=1 to INTRQ set (When the drive is in idle mode)
From BSY=1 to INTRQ set (When the drive is in standby mode)
NON-DATA COMMANDS
From writing to command register to BSY=1
From BSY=1 to INTRQ set (When the drive is in standby mode)
DMA DATA TRANSFER COMMANDS
From writing to command register to BSY=1
Copyright ©2000 Toshiba corporation. All rights reserved.
- 626 -
Function and Intervals
Table 11.6-1 Other timings.
Timeout
400 ns
maximum
31 s
maximum
400 ns
maximum
10 sec
maximum
400 ns
maximum
31 sec
maximum
400 ns
maximum
20 sec
maximum
35 sec
maximum
minimum
5 s
400 ns
maximum
400 ns
maximum
minimum
5 s
10 sec
maximum
25 sec
maximum
400 ns
maximum
17 sec
maximum
400 ns
maximum