Other Timings - Toshiba MK3006GAL Specification

1.8 inch hard disk drive
Hide thumbs Also See for MK3006GAL:
Table of Contents

Advertisement

11.6 Other timings

See HOST INTERFACE section for timings which are not shown here.
• POWER ON TIMINGS
From power on to BSY=1
From Power on to BSY=0, DRDY=1
• SOFT RESET TIMINGS
From soft reset assertion (SRST=1) to BSY=1
From soft reset negation (SRST=0) to drive ready (BSY=0, DRDY=1)
• HARD RESET TIMINGS
From hard reset assertion to BSY=1
From hard reset negation to drive ready (BSY=0, DRDY=1)
• DATA IN COMMANDS
From writing to command register to BSY=1
From BSY=1 to BSY=0, DRQ=1, INTRQ set (When the drive is in idle mode)
From BSY=1 to BSY=0, DRQ=1, INTRQ set (When the drive is in standby mode)
Drive Busy during data transfer
• DATA OUT COMMANDS
From writing to command register to BSY=1
From BSY=1 to BSY=0, DRQ=1
Drive Busy during data transfer
From BSY=1 to INTRQ set (When the drive is in idle mode)
From BSY=1 to INTRQ set (When the drive is in standby mode)
• NON-DATA COMMANDS
From writing to command register to BSY=1
From BSY=1 to INTRQ set (When the drive is in standby mode)
• DMA DATA TRANSFER COMMANDS
From writing to command register to BSY=1
(*1) When the following commands are issued by the host as First Command after hardware reset, the command's
time-out value of the field is 10 seconds.
Security Diable Password
Security Erase Unit
Security Set Password
Security Unlock
Table 11.6-1 Other timings.
Function and Intervals
Toshiba Corporation Digital Media Network Company
Page 157 of 157
© 2005, Copyright TOSHIBA Corporation All Rights Reserved
Timeout
400 ns
maximum
31 s
maximum
400 ns
maximum
10 sec
maximum
400 ns
maximum
31 sec
maximum
400 ns
maximum
20 sec
maximum
35 sec
maximum
5 µs
minimum
400 ns
maximum
700 µs(*1)
maximum
5 µs
minimum
10 sec
maximum
25 sec
maximum
400 ns
maximum
17 sec
maximum
400 ns
maximum