1 FUNCTION
The detector is designed to detect destruction
of glasses, glazed structures of enclosed area
and generate an alarm notification by opening
of signaling relay
contacts.
2 DETECTION ZONE
1
2
2
5,2 m
5,2 m
1
Confident detection area
Probable detection area
2
(for determination procedure see p.9)
3 SPECIFICATIONS
Maximal detection range, m ........................... 6
Operating frequencies:
first, Hz .............................................. 6000±100
second, Hz ............................................. 150±10
Power supply voltage, V ............. from 8 up to 15
Current consumption, mA, max ......................12
Overall dimensions, mm ..................... 87×55×28
Operating Conditions
Temperature range, °С ........ from - 20 up to +50
Relative air humidity, % ........... up to 95 at +35 °С
Without moisture condensation
4 DELIVERY SET
Delivery set includes: dowel – 2 pcs., screw – 2
pcs., user guide – 1 pcs.
5 MODES OF OPERATION
Plug
name
Interference
indication ON
Green
Interference
indication OFF
Alarm indication
ON
Red
Alarm indication
OFF
"Alarm
memory"
ON
Mem
"Alarm
memory"
OFF
Min sensitivity
Low sensitivity
Sens0
Sens1
High sensitivity
Max sensitivity
Jumper
position

Advertisement

loading

Summary of Contents for teko Astra-GB

  • Page 1 Delivery set includes: dowel – 2 pcs., screw – 2 The detector is designed to detect destruction pcs., user guide – 1 pcs. of glasses, glazed structures of enclosed area and generate an alarm notification by opening Astra-GB of signaling relay contacts. 5 MODES OF OPERATION Acoustic Glass Break...
  • Page 2 RES – terminating resistor connection terminal; 4) Mount on a wall. 3) Push out wire 6 INSTALLATION PLACE TMP – detector tampering control terminals; insertion holes caps. RELAY – terminals for detector connection to Recommended installation height is at least 2m and at a distance not more than 6m from alarm loop (zone);...