Bypass Function Bytes; Supervisory Function Bytes; Opening And Closing Function Bytes - DSC MAXSYS PC4400 Installation Manual

Table of Contents

Advertisement

Bypass Function Bytes

In the following list, there are two entries for each event in the Function Byte column. The first number corresponds to the
bypassing of a zone; the second corresponds to the unbypassing. Each event will thus be printed in one of two ways.
For example:
46
Burglar
C6
Burglar
Function Byte
Printer Message
40/C0
Fire*
41/C1
Sprnklr *
42/C2
Panic*
43/C3
Hold up*
44/C4
Medical*
45/C5
Emergen*
46/C6
Burglar*
47/C7
DelayHA*
48/C8
Delay*
49/C9
Instant*
4A/CA
Interio*
4B/CB
InterHA*
4C/CC
Motion*
4D/CD
Water*
4E/CE
Freeze*
4F/CF
Gas*
50/D0
Heat*

Supervisory Function Bytes

In the following list, there are two entries for each event in the Function Byte column. The first number corresponds a supervi-
sory; the second corresponds to a supervisory restoral. Each event will thus be printed in one of two ways.
For example:
66
Burglar
E6
Burglar
Function Byte
Printer Message
60/E0
Fire*
61/E1
Sprinkl*
62/E2
Panic*
63/E3
Hold up*
64/E4
Medical*
65/E5
Emergen*
66/E6
Burglar*
67/E7
DelayHA*
68/E8
Delay*
69/E9
Instant*
6A/EA
Interio*
6B/EB
InterHA*

Opening and Closing Function Bytes

In the following list, there are two entries for each event in the Function Byte column. The first number corresponds an open-
ing; the second corresponds to a closing. Each event will thus be printed in one of two ways. For example:
76
Open User XXX
F6
Close User XXX
Function Byte
Printer Message
76/F6
Open/Close User000-999
77/F7
Open/Close Group000-999
16
Byp ZnXXX
BB XXX
Unb ZnXXX
BU XXX
Computer Message
FB/FU 000-999
SB/SU 000-999
PB/PU 000-999
HB/HU 000-999
MB/MU 000-999
QB/QU 000-999
BB/BU 000-999
BB/BU 000-999
BB/BU 000-999
BB/BU 000-999
BB/BU 000-999
BB/BU 000-999
BB/BU 000-999
WB/WU 000-999
ZB/ZU 000-999
GB/GU 000-999
KB/KU 000-999
Sup Zn001
BS 001
S_R Zn001
BJ 001
Computer Message
FS/FJ 000-999
SS/SJ 000-999
PS/PJ 000-999
HS/HJ 000-999
MS/MJ 000-999
QS/QJ 000-999
BS/BJ 000-999
BS/BJ 000-999
BS/BJ 000-999
BS/BJ 000-999
BS/BJ 000-999
BS/BJ 000-999
OP XXX
CL XXX
Computer Message
OP/CL 000-999
OG/CG 000-999
firealarmresources.com
This event is a bypass.
This event is an unbypass.
Function Byte Printer Message
51/D1
24 Hrs*
52/D2
System*
53/D3
Auxil.*
54/D4
Untyped*
55/D5
-------*
56/D6
24hrLat*
57/D7
Tamper*
58/D8
Supervi *
59/D9
Group*
5A/DA
-------*
5B/DB
-------*
5C/DC
-------*
5D/DD
-------*
5E/DE
-------*
5F/DF
-------*
*The zone number of each alarm and restoral will also be
printed in the form of "Byp/Unb Zn000-999".
This event is a supervisory.
This event is an supervisory restore.
Function Byte Printer Message
6C/EC
Motion*
6D/ED
Water*
6E/EE
Freeze*
6F/EF
Gas*
70/F0
Heat*
71/F1
24 Hrs *
72/F2
System*
73/F3
Auxil.*
74/F4
Untyped*
75/F5
-------*
*The zone number of each alarm and restoral will also be
printed in the form of "Sup/S_R Zn000-999".
This event is a opening.
This event is an closing.
Computer Message
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
TB/TU 000-999
TB/TU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
Computer Message
BS/BJ 000-999
WS/WJ 000-999
ZS/ZJ 000-999
GS/GJ 000-999
KS/KJ 000-999
US/UJ 000-999
US/UJ 000-999
US/UJ 000-999
US/UJ 000-999
US/UJ 000-999

Advertisement

Table of Contents
loading

Table of Contents