Bypass Function Bytes
In the following list, there are two entries for each event in the Function Byte column. The first number corresponds to the
bypassing of a zone; the second corresponds to the unbypassing. Each event will thus be printed in one of two ways.
For example:
46
Burglar
C6
Burglar
Function Byte
Printer Message
40/C0
Fire*
41/C1
Sprnklr *
42/C2
Panic*
43/C3
Hold up*
44/C4
Medical*
45/C5
Emergen*
46/C6
Burglar*
47/C7
DelayHA*
48/C8
Delay*
49/C9
Instant*
4A/CA
Interio*
4B/CB
InterHA*
4C/CC
Motion*
4D/CD
Water*
4E/CE
Freeze*
4F/CF
Gas*
50/D0
Heat*
Supervisory Function Bytes
In the following list, there are two entries for each event in the Function Byte column. The first number corresponds a supervi-
sory; the second corresponds to a supervisory restoral. Each event will thus be printed in one of two ways.
For example:
66
Burglar
E6
Burglar
Function Byte
Printer Message
60/E0
Fire*
61/E1
Sprinkl*
62/E2
Panic*
63/E3
Hold up*
64/E4
Medical*
65/E5
Emergen*
66/E6
Burglar*
67/E7
DelayHA*
68/E8
Delay*
69/E9
Instant*
6A/EA
Interio*
6B/EB
InterHA*
Opening and Closing Function Bytes
In the following list, there are two entries for each event in the Function Byte column. The first number corresponds an open-
ing; the second corresponds to a closing. Each event will thus be printed in one of two ways. For example:
76
Open User XXX
F6
Close User XXX
Function Byte
Printer Message
76/F6
Open/Close User000-999
77/F7
Open/Close Group000-999
16
Byp ZnXXX
BB XXX
Unb ZnXXX
BU XXX
Computer Message
FB/FU 000-999
SB/SU 000-999
PB/PU 000-999
HB/HU 000-999
MB/MU 000-999
QB/QU 000-999
BB/BU 000-999
BB/BU 000-999
BB/BU 000-999
BB/BU 000-999
BB/BU 000-999
BB/BU 000-999
BB/BU 000-999
WB/WU 000-999
ZB/ZU 000-999
GB/GU 000-999
KB/KU 000-999
Sup Zn001
BS 001
S_R Zn001
BJ 001
Computer Message
FS/FJ 000-999
SS/SJ 000-999
PS/PJ 000-999
HS/HJ 000-999
MS/MJ 000-999
QS/QJ 000-999
BS/BJ 000-999
BS/BJ 000-999
BS/BJ 000-999
BS/BJ 000-999
BS/BJ 000-999
BS/BJ 000-999
OP XXX
CL XXX
Computer Message
OP/CL 000-999
OG/CG 000-999
firealarmresources.com
This event is a bypass.
This event is an unbypass.
Function Byte Printer Message
51/D1
24 Hrs*
52/D2
System*
53/D3
Auxil.*
54/D4
Untyped*
55/D5
-------*
56/D6
24hrLat*
57/D7
Tamper*
58/D8
Supervi *
59/D9
Group*
5A/DA
-------*
5B/DB
-------*
5C/DC
-------*
5D/DD
-------*
5E/DE
-------*
5F/DF
-------*
*The zone number of each alarm and restoral will also be
printed in the form of "Byp/Unb Zn000-999".
This event is a supervisory.
This event is an supervisory restore.
Function Byte Printer Message
6C/EC
Motion*
6D/ED
Water*
6E/EE
Freeze*
6F/EF
Gas*
70/F0
Heat*
71/F1
24 Hrs *
72/F2
System*
73/F3
Auxil.*
74/F4
Untyped*
75/F5
-------*
*The zone number of each alarm and restoral will also be
printed in the form of "Sup/S_R Zn000-999".
This event is a opening.
This event is an closing.
Computer Message
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
TB/TU 000-999
TB/TU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
UB/UU 000-999
Computer Message
BS/BJ 000-999
WS/WJ 000-999
ZS/ZJ 000-999
GS/GJ 000-999
KS/KJ 000-999
US/UJ 000-999
US/UJ 000-999
US/UJ 000-999
US/UJ 000-999
US/UJ 000-999