11

DISASSEMBLY PROCEDURE

1. INDOOR UNIT (PEH-3EKHA
OPERATING PROCEDURE
1. Removing the drain pan
(1) Unscrew each set screw on the right and left, and
remove the drain pan pushing it toward the back.
2. Removing the electrical parts
(1) Remove the 2 screws and the electrical parts cover.
Indoor controller board
Transformer
Run capacitor
Fuse (1A, 2A, 5A)
Surge absorber
Terminal block
Thermistor (for indoor temperature)
3. Removing the indoor coil thermistor
(1) Remove the drain pan.
(2) Remove the electrical parts cover.
(3) Remove the set wire of thermistor.
.TH)
2
(See Photo 1.)
(See Photo 2.)
(See Photo 3.)
(See Photo 1.)
(See Photo 2.)
(See Photo 4.)
PHOTOS
Photo 1
Room temperature
thermistor
Drain pan
Photo 2
Photo 3
Connector
Terminal
Surge
Indoor
block
absorber
controller board
Photo 4
Set screw
(for drain pan)
Electrical
parts cover
Set
screw
Fuse
Transformer
Run capacitor
Indoor coil
thermistor
Fan motor
49