Mitsubishi Electric Mr.SLIM PEH Series Technical & Service Manual page 26

Split-type, heat pump air conditioners
Table of Contents

Advertisement

2-2 DRY operation
<DRY operation time chart>
ON
Thermostat
OFF
ON
Indoor fan
OFF
ON
Booster heater
OFF
ON
Compressor
OFF
w1 Even if the room temperature rises above the set temperature during this period, the compressor will not start until this period has ended.
(1) Compressor control
13-minute time delay
To prevent overload, the compressor will not start within 3 minutes after stop.
2The compressor runs when the room temperature is higher than the set temperature.
The compressor stops when the room temperature is equal to or lower than the set temperature.
3The compressor stops in check mode or during protective functions.
26
FILTER
CHECK MODE
TEST RUN
Operation starts by
P O W E R b u t t o n
ON.
Low speed
OFF
<How to operate>
1 Press POWER ON/OFF button.
2 Press the
3 Press the
TEMP button to set the desired temperature.
NOTE: The set temperature changes 1°C when the
button is pressed one time.
Dry 19 to 30°C
Room temperature
Room temperature
becomes equal to
rises above set
set temperature.
temperature.
Minimum 3 minutes w1
button to display "
"
Operation stops by
P O W E R b u t t o n
OFF.
LOW speed
or