18) When the flush mode has started, pour the cleaning solution prepared in 16)
carefully into the water tank within 60 seconds before the pump motor starts. Do not
splash or spill the solution onto the other parts.
19) Circulate the sanitizing solution for 15 minutes. Push the reset switch to open the
water pan. Unplug the icemaker or disconnect the power source when the water pan
has fully opened. Wait until the sanitizing solution has completely drained out.
20) Open the water supply tap, and repeat the above step 9). Since the water supply tap
is open this time, water is supplied as in the normal freeze cycle.
21) When the water pan closes again, pour clean water into the water pan until it floods
from the overflow pipe, and circulate the water for 5 minutes.
22) Push the reset switch to open the water pan and drain the water. This time the water
does not drain out completely.
23) Repeat the above steps 21) and 22) at least three times to rinse thoroughly. To drain
the rinse water completely, unplug the icemaker or disconnect the power source
when the water pan has fully opened.
24) Move the tank drain pipe to the normal position, and secure it with the screw. See
Fig. 1.
25) Plug in the icemaker or connect the power source. Check for proper icemaking
operation.
26) Replace the front panel and top panel in their correct positions.
27) Complete storage bin cleaning as detailed in IV. 1. [3].