Page 1
IM-240DNE MODULAR CUBER IM-240XNE MACHINE A GLAÇONS MODULAIRE IM-240DWNE MODULARER WÜRFELEISBEREITER IM-240XWNE IJSBLOKJESMACHINE MET LOSSE OPSLAGBUNKER IM-240DSNE FABRICADOR MODULAR DE CUBITOS DE HIELO IM-240XSNE CUBETTATRICE MODULARE IM-240DNE-C IM-240XNE-C IM-240DWNE-C INSTALLATION MANUAL IM-240XWNE-C NOTICE D’INSTALLATION INSTALLATIONSANLEITUNG INSTALLATIE VOORSCHRIFT MANUAL DE INSTALACION MANUALE PER L’INSTALLAZIONE...
Page 2
50 cm at the right side (air-cooled model) or 15 cm clearance at rear, sides and top (water-cooled model) for proper air circulation and ease of maintenance and/or Note: This icemaker needs a Storage Bin. Hoshizaki recommends the service should they be required. following Ice Storage Bins: B801SA (Top Kit IMD) -------IM-240D/IM-480D/IM-720D 5.
ENGLISH 3. INSTALLATION 2) Remove the icemaker panels. The Rear Panel is not required to be removed for installation. See “1. UNPACKING”. * Incorrect installation can cause 3) Attach the lower unit (X-type) on the top of the Storage Bin. See harm to people, animals or things, Bottom Fig.
Note: If stacking three icemakers, repeat the instructions 6) - 11) for Supply of replacement fuse covers can be obtained from Hoshizaki the upper unit. Remember, only ONE Bin Control is needed Parts/Service Centres.
Page 5
ENGLISH [Water-Cooled Model] * Hoshizaki recommends that the water-cooled Condenser should be connected to a closed circuit recirculating type cooling system Water Inlet (IM-720) utilizing a tower, water chiller or similar (see Fig. 15 and 16). Water *Cooling Water Inlet make up should be via a ball valve/break tank arrangement.
ENGLISH 7. START-UP PROCEDURE Icemaker Potable Water 1) Open the water tap. Inlet G3/4 Cooling Water 2) Connect the power supply and energise. Inlet Rc1/2 1/2-3/4 3) The Display indicates “on”. Nipple Cooling Water Outlet Rc1/2 4) The following should occur in sequence: a) Hot Gas Valve will open.