Table of Contents

Advertisement

Quick Links

© Copyright 2020
EVERTZ MICROSYSTEMS LTD.
5292 John Lucas Drive
Burlington, Ontario
Canada L7L 5Z9
Phone:
+1 905-335-3700
Sales:
sales@evertz.com
Tech Support: service@evertz.com
Web Page:
http://www.evertz.com
Version 1.0, March 2020
The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of
purchasers of the 570ASI–X19-10GE2 series product. Evertz Microsystems expressly prohibits the use of this manual for any purpose other than
the operation of the 570ASI–X19-10GE2 series product. Due to on going research and development, features and specifications in this manual
are subject to change without notice.
All rights reserved. No part of this publication may be reproduced without the express written permission of Evertz Microsystems Ltd. Copies of
this manual can be ordered from your Evertz dealer or from Evertz Microsystems.
570ASI-X19-10GE2 Series
User Manual
Fax: +1 905-335-3573
Fax: +1 905-335-7571

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 570ASI-X19-10GE2 and is the answer not in the manual?

Questions and answers

Summary of Contents for evertz 570ASI-X19-10GE2

  • Page 1 Version 1.0, March 2020 The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of purchasers of the 570ASI–X19-10GE2 series product. Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the 570ASI–X19-10GE2 series product.
  • Page 2 This page left intentionally blank...
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “Dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (Servicing) instructions in the literature accompanying the product.
  • Page 4 WARNING Changes or Modifications not expressly approved by Evertz Microsystems Ltd. could void the user’s authority to operate the equipment. Use of unshielded plugs or cables may cause radiation interference. Properly shielded interface cables...
  • Page 5 Evertz products are for informational use only and are not warranties of future performance, either expressed or implied. The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty, stated in the sales contract or order confirmation form.
  • Page 6 570ASI–X19-10GE2 Series User Manual This page left intentionally blank Page - ii...
  • Page 7: Table Of Contents

    570ASI–X19-10GE2 Series User Manual TABLE OF CONTENTS OVERVIEW ........................... 1 SPECIFICATIONS ......................... 3 2.1. SERIAL DIGITAL VIDEO ...................... 3 2.2. SERIAL VIDEO/ASI INPUT ....................3 2.3. IP INPUT ..........................3 2.4. SERIAL VIDEO/ASI OUTPUT ....................3 2.5. IP OUTPUT ........................... 3 2.6.
  • Page 8 570ASI–X19-10GE2 Series User Manual 4.4. DIN INPUT CONTROL ....................... 18 4.4.1. Input Monitoring ...................... 18 4.5. PTP AND MASTER PCR CONTROL ................. 19 4.5.1. PTP and Master PCR Control ................. 19 4.5.2. PTP Control ......................20 4.5.3. Master PCR Control ....................20 4.6.
  • Page 9 570ASI–X19-10GE2 Series User Manual Figures Figure 3-1: 570ASI–X19-10GE2 Front (Left) and Rear Plate (Right)............... 5 Figure 4-1: WebEASY - Login Menu ......................7 ® Figure 4-2: WebEASY - Top Navigation Bar ....................7 ® Figure 4-3: WebEASY - Side Menu ........................ 8 ®...
  • Page 10 570ASI–X19-10GE2 Series User Manual This page left intentionally blank Page - vi...
  • Page 11: Overview

    570ASI–X19-10GE2 Series User Manual OVERVIEW The 570ASI–X19-10GE2 platform is a complete solution to concurrently convert SDI to SMPTE ST 2022–6/2110, SMPTE ST 2022–6/2110 to SDI*, ASI to IP and IP to ASI. The 570ASI–X19-10GE2 is a high density, high performance encap/de–encapsulator. With a truly unique and flexible design, the 570ASI–X19-10GE2 supports a variety of operating modes depending on the APP loaded.
  • Page 12 570ASI–X19-10GE2 Series User Manual This page left intentionally blank Page - 2...
  • Page 13: Specifications

    570ASI–X19-10GE2 Series User Manual SPECIFICATIONS 2.1. SERIAL DIGITAL VIDEO Standards: SMPTE ST 424M (3Gb/s), SMPTE ST 292M (1.5Gb/s), SMPTE ST 259M (270Mb/s) SMPTE ST 2022–6 2.2. SERIAL VIDEO/ASI INPUT Number of Inputs: 570ASI–APP–ASI: 10x ASI 570ASI–APP–IPG: 6x SDI/ASI Connector: Input Equalization: Automatic to 100m @ 3 Gb/s, 150m @ 1.5 Gb/s, 350m @ 270 Mb/s...
  • Page 14: Electrical

    570ASI–X19-10GE2 Series User Manual 2.6. ELECTRICAL Power: Voltage: 12VDC EMI/RFI: Complies with FCC Part 15, Class A EU EMC directive 2.7. ENCLOSURES 570FR: 3RU chassis S570FR: 1RU chassis 2.8. ORDERING INFORMATION 570ASI–X19: Bulk IP/ASI media processor, up to 12x 10GbE interfaces using SFP+ cages (SFPs sold separately).
  • Page 15: Getting Started

    570ASI–X19-10GE2 Series User Manual GETTING STARTED Figure 3-1: 570ASI–X19-10GE2 Front (Left) and Rear Plate (Right) 3.1. FRONT PLATE The front of the 570ASI–X19-10GE2 is equipped with 12x SFPs ports capable of passing 10Gb of data per port. 3.2. BACK PLATE The rear plate of the 570ASI–X19-10GE2 is equipped with 20 Mini-Din connectors.
  • Page 16: Care And Handling Of Optical Fiber

    Evertz recommends that the user maintains a minimum bending radius of 5 cm to avoid fiber bending loss that will decrease the maximum attainable distance of the fiber cable.
  • Page 17: Web Interface

    Note: We are assuming that the 570FR or S570FR frame is connected to the network and the computer is able to communicate to the frame on the Control Port IP address of the 570ASI–X19 570ASI-X19-10GE2 Figure 4-1: WebEASY - Login Menu ®...
  • Page 18: Figure 4-3: Webeasy - Side Menu

    570ASI–X19-10GE2 Series User Manual Figure 4-3: WebEASY - Side Menu ® • Side Menu: Displays a menu of all tabs the user is able to monitor/configure. • Main Tab: Middle section of the interface, displays all the fields for the item selected from the side menu.
  • Page 19: System

    570ASI–X19-10GE2 Series User Manual 4.1. SYSTEM Figure 4-4: WebEASY - System (Part 1 of 2) ® Page - 9...
  • Page 20: Control Port Configuration

    570ASI–X19-10GE2 Series User Manual 4.1.1. Control Port Configuration For Eth0 or USB0 MAC Address: This field displays the MAC Address of the 570ASI–X19-10GE2. IP Address: This field allows the user to enter the IP address to be assigned to control port of the 570ASI–X19-10GE2.
  • Page 21: Temperature Monitor

    “570asi_config.json” on a local PC. Configuration files are useful for backing up a card’s settings for future use or to aid Evertz technical support for debugging purposes. Note that when the user saves a configuration, it saves all subscribed routes that were present on the card.
  • Page 22: Card Control

    - Product Features ® Product Serial Number: This field displays the serial number of the 570ASI-X19. Evertz requires you to provide this serial number when requesting a product license. Product Mac Address: This field displays the MAC address of the Product.
  • Page 23: Ip Input Control

    570ASI–X19-10GE2 Series User Manual 4.3. IP INPUT CONTROL Figure 4-8: WebEASY - IP Input Control (Part 1 of 2) ® Page - 13...
  • Page 24: Mppm Control

    570ASI–X19-10GE2 Series User Manual 4.3.1. MPPM Control For IP Inputs 1 to 6 Link Select: The link select control allows the user to configure the decoder link to Auto Packet Merge, Main, Backup or Fail Over. Auto Packet Merge: Selecting this control will force the de-encapsulator link to merge valid packets •...
  • Page 25 570ASI–X19-10GE2 Series User Manual IGMPV3 SSM Src <1-6> IP Address: This parameter allows the user to set IP addresses which will be used while forming the source filter “SSM sources” for IGMPV3 communications. Page - 15...
  • Page 26: Figure 4-9: Webeasy - Ip Input Control (Part 2 Of 2)

    570ASI–X19-10GE2 Series User Manual Figure 4-9: WebEASY - IP Input Control (Part 2 of 2) ® Page - 16...
  • Page 27: Audio Group 1-4 Ip Input

    570ASI–X19-10GE2 Series User Manual 4.3.6. Audio Group 1-4 IP Input for SFPP 1 to 6 IP Input Status: This parameter indicates if the selected input stream type, MPPM mode, and SFP selections have enabled usage of this audio group’s IP address. Audio Group IP Address: This parameter allows the user to select the input IP address / multicast address for the audio that they want to receive.
  • Page 28: Din Input Control

    570ASI–X19-10GE2 Series User Manual 4.4. DIN INPUT CONTROL Figure 4-10: WebEASY - DIN Input Control ® 4.4.1. Input Monitoring For DIN Inputs 1 to 6 Input Detected: The 570ASI-X19 card can accept both SDI and ASI sources. The 570ASI-X19 will automatically detect the DIN Input type provided.
  • Page 29: Ptp And Master Pcr Control

    570ASI–X19-10GE2 Series User Manual 4.5. PTP AND MASTER PCR CONTROL Figure 4-11: WebEASY - PTP and Master PCR Control ® 4.5.1. PTP and Master PCR Control PTP or Master PCR Selection: This parameter allows the user to select the reference as either PTP or Master PCR.
  • Page 30: Ptp Control

    570ASI–X19-10GE2 Series User Manual Fail Over Mode Selection: This dropdown allows the user to select the failover mode for the received master PCR stream. • Automatic • Main • Backup Fail Over Status: This parameter displays the current status of the master PCR fail over. PTP or Master PCR Presence: This parameter indicates whether a valid Master PCR is present or a valid PTP stream is present.
  • Page 31: Ip Output Control

    570ASI–X19-10GE2 Series User Manual 4.6. IP OUTPUT CONTROL Figure 4-12: WebEASY - IP Output Control ® Page - 21...
  • Page 32: Configuration

    570ASI–X19-10GE2 Series User Manual 4.6.1. Configuration For IP Outputs 1 to 6 IP Output Configuration: This control configures how to process the incoming streams into the outgoing streams Uncompressed Encap Rate Limit: This dropdown allows the user to set the bandwidth limit of uncompressed encapsulated streams.
  • Page 33: Uncompressed Ip Output Control

    570ASI–X19-10GE2 Series User Manual 4.6.3. Uncompressed IP Output Control For IP Outputs 1 to 6 IP Output Enable: This parameter is used to enable or disable an output. Source IP Address: This parameter allows the user to define source IP address. Source UDP Port: This parameter allows the user to define source UDP port.
  • Page 34: Din Output Control

    570ASI–X19-10GE2 Series User Manual 4.7. DIN OUTPUT CONTROL Figure 4-13: WebEASY - DIN Output Control ® 4.7.1. Output Control For DIN Outputs 1 to 6 Output Interface Format: This field displays the Output Interface Format for the selected DIN output. Default ASI Type Selection: This control allows the user to select which ASI output type is sent out when receiving an ASI encapsulated feed.
  • Page 35: System Notify

    570ASI–X19-10GE2 Series User Manual 4.8. SYSTEM NOTIFY Figure 4-14: WebEASY - System Notify ® 4.8.1. System Monitoring Control Temperature Warning Threshold: This control allows the user to set the temperature threshold. If the temperature exceeds the configured temperature threshold, the temperate status will change to active. 4.8.2.
  • Page 36: Asi Input Notify

    570ASI–X19-10GE2 Series User Manual 4.9. ASI INPUT NOTIFY Figure 4-15: WebEASY - ASI Input Notify ® 4.9.1. ASI Input Alarm Control CC Error Threshold: This control sets the Closed Captioning Error Threshold before an alarm is sent. Time Frame (1 to 600): This control sets the period, in seconds, over which the threshold can surpass. 4.9.2.
  • Page 37: Ip Input Notify

    570ASI–X19-10GE2 Series User Manual 4.10. IP INPUT NOTIFY Figure 4-16: WebEASY - IP Input Notify ® 4.10.1. IP Input Notify Controls Minimum Received Bandwidth Threshold: This control sets the minimum amount of bandwidth that must be present before an alarm is sent. 4.10.2.
  • Page 38: Snmp Setup

    570ASI–X19-10GE2 Series User Manual 4.11. SNMP SETUP Figure 4-17: WebEASY - SNMP Setup ® 4.11.1. SNMPv1 Trap Destinations Add Trap Destination: This parameter allows the user to enter a new SNMPv1 trap destination IP address. Trap Destination 1 to 10: These Parameters show the current SNMPv1 trap destination IP address. Clear Button: Each of these buttons clear the IP address displayed for its respective trap destination.
  • Page 39: Firmware Upgrade

    Selecting the Upgrade tab, will open a new window as shown in Figure 5-2 where the current firmware version is shown. Should the firmware version be outdated, the user will need to download the firmware image file.  Note: Contact Evertz get the latest firmware file. 570ASI–X19-10GE2 Figure 5-2: WebEASY - Firmware Upgrade Menu ®...
  • Page 40: Figure 5-3: Webeasy - Firmware Upgrade Menu

    570ASI–X19-10GE2 Series User Manual 570ASI–X19-10GE2 Step 2 Step 1 Figure 5-3: WebEASY - Firmware Upgrade Menu ® Once selected, click Open (Step 1) to advance to next step. Click Upgrade (Step 2) and watch progress bar for status. Once completed, the device will automatically restart. Page - 30...

Table of Contents