No.
Error messages
1
INPUT-A POWER ALERT
2
INPUT-B POWER ALERT
3
INPUT-C POWER ALERT
4
INPUT-D POWER ALERT
5
PR-284_1 POWER ALERT
6
PR-284_2 POWER ALERT
7
PR-284_3 POWER ALERT
8
PR-284_4 POWER ALERT
9
24V POWER SUPPLY ALERT
10
16V POWER SUPPLY ALERT
11
PR-284_1 DETACHED
12
SXRD PANEL TEMPERATURE
ALERT
13
LAMP_A FAN ALERT
14
LAMP_B FAN ALERT
15
LAMP_A POWER SUPPLY UNIT
FAN ALERT
16
LAMP_B POWER SUPPLY UNIT
FAN ALERT
17
PR-284 FAN ALERT
18
OPTICAL UNIT TEMPERATURE
ALERT
19
LAMP_A TEMPTEMPERATURE
ALERT
20
LAMP_B TEMPTEMPERATURE
ALERT
21
LAMP_A HOUSE DETACHED
22
LAMP_B HOUSE DETACHED
23
REAR COVER DETACHED
24
LAMP_A POWER SUPPLYUNIT
ALERT
25
LAMP_B POWER SUPPLY UNIT
ALERT
26
LAMP_A IGNITION FAILURE
27
LAMP_B IGNITION FAILURE
28
CPU ALERT
29
MUTING OFF FAILURE
DOUSER OPEN FAILURE
30
INPUT BOARD FAN ALERT
Meaning
Trouble with power of INPUT A board
Trouble with power of INPUT B board
Trouble with power of INPUT C board
Trouble with power of INPUT D board
Trouble with power of PR-284 board at the top
Trouble with power of PR-284 board on the second row
Trouble with power of PR-284 board on the third row
Trouble with power of PR-284 board on the fourth row
The projector has failed to supply 24V power.
The projector has failed to supply 16V power.
The PR-284 board is not attached correctly on the top row.
The temperature of the panels is too high.
Trouble with the for Lamp A, or the harness is disconnected or down.
Trouble with the for Lamp B, or the harness is disconnected or down.
Trouble with the ballast fan for Lamp A power, or the harness is disconnected or down.
Trouble with the ballast fan for Lamp B power, or the harness is disconnected or down.
Trouble with the fan for PR-284 board, or the harness is disconnected or down.
The temperature of the optical unit is too high, or the harness is disconnected or down.
The temperature of Lamp A is too high, or the harness is disconnected or down.
The temperature of Lamp B is too high, or the harness is disconnected or down.
The projection lamp house of Lamp A is not installed correctly, or the harness is
disconnected or down.
The projection lamp house of Lamp B is not installed correctly, or the harness is
disconnected or down.
The rear cover is open, or the harness is disconnected or down.
Trouble with the power (ballast) of Lamp A
Trouble with the power (ballast) of Lamp B
Lamp A does not turn on.
Lamp B does not turn on.
Trouble with the main CPU (IC301) on the SY-321. Serious trouble
Trouble with opening/shutting of the shutter, or the harness is disconnected or down.
Trouble with the HIF fan next to the INPUT A/B/C/D boards, or the harness is
disconnected or down.