Maximum
microinverters per 20A (max) AC branch circuit
240 VAC (single phase)
CEC weighted efficiency
240 VAC (single phase)
Total harmonic distortion
Ambient temperature range
Night-time power consumption
Storage temperature range
Compatibility
Dimensions not including mounting bracket
Connector Type
Weight
Environmental Category/ UV exposure rating
Torque specifications for fasteners
(Do not over torque)
Cooling
Relative Humidity range
Approved for wet locations
Pollution degree
Standard Warranty Term
Compliance
Grounding
Monitoring
Communication
(1) No enforced DC/AC ratio. See the compatibility calculator at
DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local
requirements to define the number of microinverters per branch in your area.
34
IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation
Enphase IQ8-60-2-US Microinverter Parameters
Topic
Miscellaneous Parameters
Features and Specifications
Enphase IQ8-60-2-US Microinverter Parameters
https://link.enphase.com/module-compatibility
© 2022 Enphase Energy Inc. All rights reserved.
Unit
Min
%
%
°C
-40
mW
°C
-40
60-cell/120 half-cell PV modules
212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2")
Enphase IQ™ Connector
1.08 kg (2.38 lbs)
NEMA Type 6 / outdoor
6 mm (1/4") mounting hardware: 5 N m (45 to 50 in-lbs.)
8 mm (5/16") mounting hardware: 9 N m (80 to 85 in-lbs.)
When using UL 2703 mounting hardware, use the
manufacturer's recommended torque value
Natural convection - No fans
4% to 100% (condensing)
http://enphase.com/warranty
CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547,
FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2
NO. 107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment
and conforms with NEC 2014, NEC 2017, and NEC 2020
section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown
of PV Systems, for AC and DC conductors, when installed
according to manufacturer's instructions.
The DC circuit meets the requirements for ungrounded PV
arrays in NEC. Ground fault protection (GFP) is integrated into
the class II double insulated microinverter
Enphase Installer platform and Enphase App monitoring
options. Both options require an Enphase IQ Gateway
Power line communication (PLC)
Typical
Max
16
97%
<5
+60
60
+85
Yes
PD3
(2) Maximum continuous input
Mar 2022