Maestria WT Table of content Setting1: Manual setting of the end limits Setting 2: Semi-automatic setting of the end limits Setting 3: Automatic setting of both end limits Adjusting the end limits Adjusting the upper end limit Adjusting the down end limit...
Page 3
Setting the Maestria WT motor Setting 1: Setting of 2 fixed end limits A cable with a shunt (WT) switch is needed for setting a WT motor. This switch allows powering both directions simultaneously and it is needed to start and stop the setting process.
Page 4
Setting the Maestria WT motor 5 Setting of the upper end limit Remark: Keep the button(s) pushed until the end of the second movement Push the UP button ...a short up and down Set the end limit until… movement 6 Confirm the upper end limit...
Page 5
Setting the Maestria WT motor Setting 2: Setting of 1 fixed down end limit and an automatic upper end limit. After the setting, the bottom bar will compensate the fabric lengthening every 30 cycles. After 180 cycles, this frequency will change to every 90 cycles. A cable with a shunt (WT) switch is needed for setting a WT motor.
Page 6
Setting the Maestria WT motor 5 Setting the down end limit Remark: Keep the button(s) pushed until the end of the second movement Push the UP button ...short up and down Set the end limit until... movement 6 Confirm the down end limit...
Page 7
Setting the Maestria WT motor Setting 3: Setting of 2 automatic end limits After the setting, the bottom bar will compensate the fabric lengthening every 30 cycles. After 180 cycles, this frequency will change to every 90 cycles. A cable with a shunt (WT) switch is needed for setting a WT motor.
Page 8
Setting the Maestria WT motor 5 Activeate the full automatic mode Remark: Keep the button(s) pushed until the end of the second movement. Push the up button ...short up and down Push the WT ...short up and down until… movement button until...
Adjusting end limits on the WT motors (for motors from 2015) Adjusting the upper end limit of a Maestria WT motor (fixed end limit), an Oximo WT motor (fixed end limit) or an Altus WT motor A cable with a shunt (WT) switch is needed for setting a WT motor. This switch allows powering both directions simultaneously and it is needed to start and stop the setting process.
Adjusting end limits on the WT motors (for motors from 2015) 5 Adjusting the upper end limit Remark: Keep the button(s) pushed ±6 s until the end of the second movement Push the UP button for 5 s, Push the UP button ...short up and down then wait 2 s until...
Page 11
Adjusting end limits on the WT motors (for motors from 2015) Adjusting the down end limit of a Maestria WT motor (fixed end limit), an Oximo WT motor (fixed end limit), an Altus WT motor or an Orea WT motor A cable with a shunt (WT) switch is needed for setting a WT motor.
Adjusting end limits on the WT motors (for motors from 2015) 5 Adjusting the down end limit Remark: Keep the button(s) pushed ±6 s until the end of the second movement Push the DOWN button Push the DOWN ...short up and down for 5 s, then wait 2 s button until...
Setting the Maestria WT motor Activate the obstacle detection A cable with a shunt (WT) switch is needed for setting a WT motor. This switch allows powering both directions simultaneously and it is needed to start and stop the setting process.
Page 14
Setting the Maestria WT motor 5 Activate the setting mode Execute the next Remark: step within 10 s. Keep the button(s) pushed until the end of the second movement Keep the WT button ...short up and down pushed until... movement...
Page 15
Setting the Maestria WT motor De-activation of the obstacle detection A cable with a shunt (WT) switch is needed for setting a WT motor. This switch allows powering both directions simultaneously and it is needed to start and stop the setting process.
Setting the Maestria WT motor 5 Activate the setting mode Execute the next Remark: step within 10 s. Keep the button(s) pushed until the end of the second movement Keep the WT button ...short up and down pushed until... movement...
Setting the Maestria WT motor Blocking or activating the end limit adjustment A cable with a shunt (WT) switch is needed for setting a WT motor. This switch allows powering both directions simultaneously and it is needed to start and stop the setting process.
Resetting a WT motor A cable with a shunt (WT) switch is needed for setting a WT motor. This switch allows powering both directions simultaneously and it is needed to start and stop the setting process. 1 Connect the motor using a setting cable 230V AC 2 Reset the motor ...