Consort PLE050RF Installation & Control Manual

Consort PLE050RF Installation & Control Manual

Advertisement

Q
Installation & Control Guide for Panel Convector Heaters
with Electronic Controls and Open Window Detection
PLE050RF
PLE125RF
All electrical appliances produced by the Company are guaranteed for one year against faulty
materials or workmanship.
accordance with the instructions provided and has not been connected to an unsuitable
electricity supply, or subject to misuse, neglect, damage or modified or repaired by any person
not authorised by us. This guarantee is offered to you as an extra benefit and does not affect your
legal rights.
The correct electricity supply voltage is shown on the rating label attached to the appliance.
Reasonable care has been taken to ensure that this guide is accurate at the time of printing.
In the interest of progress the Company reserve the right to vary specifications from time to time
without notice.
S
UALITY
PACE
Models
PLE075RF
PLE150RF
This applies only if the appliance has been used for purposes in
H
EATERS
PLE100RF
PLE200RF
66001079 Iss 03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PLE050RF and is the answer not in the manual?

Questions and answers

Summary of Contents for Consort PLE050RF

  • Page 1 UALITY PACE EATERS Installation & Control Guide for Panel Convector Heaters with Electronic Controls and Open Window Detection Models PLE050RF PLE075RF PLE100RF PLE125RF PLE150RF PLE200RF All electrical appliances produced by the Company are guaranteed for one year against faulty materials or workmanship.
  • Page 2: Safety And Care

    Overview appliance overheats. The TOC can only be re-set after the appliance has cooled down. In order to Please read this guide carefully and retain re-set the TOC, proceed as follows: for future use and maintenance. • Switch off appliance and leave for This appliance has been designed and approximately 10 minutes.
  • Page 3: Installation

    Installation Fig. 1 195mm ILLIMETRES ATTS PLE050/SS PLE075/SS PLE100/SS 1000 PLE125/SS 1250 PLE150/SS 1500 PLE200/SS 2000 Note: The heater MUST be fully secured in the vertical position before being switched on. It must be ‘clicked’ into the locking tabs. See section 16 for more mounting information. 66001079 Iss 03...
  • Page 4: Temp Mode

    Time Prog SET TIME SET PROGRAMME PRESS AND HOLD PRESS AND HOLD FOR 5 SECONDS FOR 5 SECONDS MODE SELECTION EMPERATURE SET Mode Temp BOOST, MANUAL, WHEN DISPLAY SHOWS SETBACK AND ROOM TEMPERATURE, PROGRAM PRESS TO ADJUST 1. Basic Operation 5.
  • Page 5 8. Set 7-day programme An example of one day programme on PLE PROGRAM 1 PROGRAM 2 PROGRAM 5 PROGRAM 6 PROGRAM PROGRAM ºC 19ºC 22ºC 22ºC 16ºC 10ºC 4ºC 06:00 08:00 12:00 14:00 16:00 22:00 Logic diagram for setting programme on PLE Press and hold PROG for 5 seconds to enter the PROG TEMP...
  • Page 6 9. Advance mode 13. Setup menu Press and hold TEMP and MODE together for 5 Press PROG from PROG mode to bring forward the next programme. To clear advance mode, press PROG. seconds. The display will enter the setup menu. 10.
  • Page 7 15. Optional PLK1 Locking Device 16. Mounting The PLK1 locking device can be used to mechanically To wall mount, the wall bracket supplied must be used. Please refer to illustrations in Fig.1. lock the controls to prevent tampering with settings. As it is not supplied with the heater, kindly contact our Sales Remove wall bracket from the heater.
  • Page 8: Declaration Of Conformity

    BSEN301 489.1 & .3 • BSEN300 220.1 & .2 • BSEN60 730.2.9 • BSEN 60335.1 (2012 ) • BS EN 60335.2.30 (2009) • PLE050RF, PLE075RF, PLE100RF, PLE125RF, UMBER ESCRIPTION PPLIANCE PLE150RF and PLE200RF Panel heaters A C R ESPONSIBLE ERSON EYNOLDS OSITION...

This manual is also suitable for:

Ple075rfPle100rfPle125rfPle150rfPle200rf

Table of Contents