Premium Series PH60 pH Tester
pH
mV
Temperature
|
|
User Manual
IP67
9001 : 2015
ISO
APERA INSTRUMENTS, LLC
aperainst.com
- 1 -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Premium Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Apera Instruments Premium Series

  • Page 1 Premium Series PH60 pH Tester Temperature User Manual IP67 9001 : 2015 APERA INSTRUMENTS, LLC aperainst.com - 1 -...
  • Page 2: Table Of Contents

    15. Troubleshooting Guide ........................11 16. Warranty ............................12 Thank you for purchasing Apera Instruments PH60 Premium pH Tester. Please read this manual before use in order to properly use and maintain the product. For video tutorials, please go to support.aperainst.com ATTENTION Ը...
  • Page 3: What's In The Kit

    1. What’s in the Kit 3M KCL Storage Solution PH60 Tester Vials holder Lanyard pH4.00 pH7.00 pH10.01 Calibration Vials pH buffer pH buffer pH buffer 2. Keypad Functions Short press: < 2 seconds Long press: > 2 seconds Battery Cap 1.
  • Page 4: Preparation Before Use

    3. Preparation before Use 3.1 Pull out the battery insulation slip, and take off the probe cap. 3.2 Rinse off the probe in pure water (preferably distilled or deionized water. RO water or tap water is the alternative) , then shake off excess water. 3.3 Perform at least a 2-point calibration.
  • Page 5 4.1.5 Wait for the reading to stabilize (when stays on the screen), then short press to finish the first point calibration. The tester returns to measurement mode and icon will appear at the bottom left, indicating a successful 1-point calibration (the middle point). 4.1.6 To calibrate second point, use pH 4.00 buffer and repeat Step 4.1.3 to 4.1.5 (Do NOT turn off the tester after you finish pH 7 calibration).
  • Page 6: Ph Measurement

    5. pH Measurement 5.1 How to take pH measurements Short press to turn on the tester. Rinse the probe in pure water, shake off excess water. Insert the probe in your sample solution, make a quick stir and hold still. Record the reading when it is stabilized ( comes up and stays on screen).
  • Page 7: Parameter Settings

    8. Parameter Settings 8.1 Setup Menu Factory Symbol Parameter Setting Contents Code Default Select pH buffer solution USA – NIST Low value measurement alarm setting 0 to 14.00pH High value measurement alarm setting 0 to 14.00pH 14.00 Auto. Hold Off – On Select backlight Off - 1 - On Select temperature unit...
  • Page 8: Orp Measurement

    8.3.6 Factory default setting (P7): Select “Yes” to set the meter to its default status (erase all calibration record and return all parameter settings to the default value). This function can be used when the meter does not work well in calibration or measurement. Calibrate the meter again after setting the meter to factory default.
  • Page 9: Other Specifications

    1-2 years depending on many factors such as frequency of use, nature of test samples, and how well it is maintained, etc. Apera Instruments recommends replacing the pH probe every 1 to 2 years to guarantee the optimal performance.
  • Page 10: Notes

    13. Notes Avoid testing in very high (>113°F) or very low (<41°F) temperature solutions as it will cause greater measurement error and potential damage to the probe. Test your samples and perform calibration close to room temperature as much as possible. b) NEVER store the probe in pure water like tap, RO, distilled, or deionized water as they could damage the pH probe.
  • Page 11: Troubleshooting Guide

    15. Troubleshooting Guide Trouble Potential Reasons How to Fix When powered on, calibrate pH 7 first, then pH 4. After pH 4 is Incorrect calibration order calibrated, if you want to calibrate pH7 again, you need to power off and restart the tester. Bad standard solutions Replace with a new reliable buffer solution.
  • Page 12: Warranty

    We warrant this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS (SIX MONTHS for the probe) from the delivery.