Apera Instruments Premium PH60S User Manual

Apera Instruments Premium PH60S User Manual

Ph tester for general purpose, spear ph tester for food and solid samples, flat ph tester for surface testing
Hide thumbs Also See for Premium PH60S:

Advertisement

Quick Links

PH60 Series Premium Line pH Testers
User Manual
PH60 pH Tester for General Purpose
PH60S Spear pH Tester for Food and Solid Samples
PH60F Flat pH Tester for Surface Testing
APERA INSTRUMENTS, LLC
aperainst.com
v7.0
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Premium PH60S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Apera Instruments Premium PH60S

  • Page 1 PH60 Series Premium Line pH Testers User Manual PH60 pH Tester for General Purpose PH60S Spear pH Tester for Food and Solid Samples PH60F Flat pH Tester for Surface Testing APERA INSTRUMENTS, LLC aperainst.com v7.0...
  • Page 2: Table Of Contents

    Thank you for purchasing Apera Instruments 60 Series Premium Line pH Tester Kit. Please read this manual carefully before use in order to properly use and maintain the product. For video tutorials, please go to support.aperainst.com Table of Contents Battery Installation ..................... 3 Keypad Functions .....................
  • Page 3: Battery Installation

    Battery Installation Please install batteries according to the following steps. Note the direction of batteries: The anode (“+”) OF EVERY SINGLE Battery MUST face UP. (WRONG INSTALLATION OF BATTERIES WILL CAUSE DAMAGE TO THE TESTER AND POTENTIAL HAZARDS ﹣ ﹣ ①...
  • Page 4: Complete Kit

    Complete Kit Preparation Before Use Things needed in addition to what’s in the box: A cup of distilled water (8-16oz) for rinsing the probe, and clean tissue paper for removing excess water. For PH60 and PH60F: If the tester hasn’t been used for a long time (> 1 month), or the tester’s response is very slow, you can soak the probe in the 3M KCL storage solution overnight before use to restore the electrode’s sensitivity.
  • Page 5 you decide to quit calibration, short press to return to measurement). 5.1.5 Stir the probe for a few seconds to eliminate potential air bubbles on the probe. 5.1.6 Allow it to stand still in the buffer solution until a stable reading is reached –...
  • Page 6: Ph Measurement

    5.3 Self-diagnosis Self-diagnostic information Icons Checking and how to fix a) Check whether pH buffer solution is correct point calibration must be 7.00). b) Check whether pH buffer solution is in good Wrong pH buffer solution or the range condition (fresh and clean) of calibration solution exceeds c) Check whether the probe is damaged.
  • Page 7: Parameter Setting

    6.3 PH60S Spear probe testers are widely used for soft solid samples containing water. When conducting such tests, pay attention to insert probe slowly, and be careful to prevent probe from damage. If the medium is too hard (such as frozen meat or some fruits), please make a small hole with a clean knife before inserting the probe.
  • Page 8 High value measurement alarm setting 0 to 14.00pH 14.00 Off – On Select automatic lock Select backlight Off - 1 - On ℃ - ℉ ℉ Select temperature unit No – Yes Restore to factory default 7.2 Parameter setup method When turned off, long press to enter parameter setting→Short press to switch P1-P2-...
  • Page 9: Orp Measurement

    7.3.4 Backlight (P5) “Off”-turn off backlight, “On”-always turn on backlight, “1”- backlight will last for 1 minute. 7.3.5 Temperature Unit (P5) Select C˚ or F˚, the factory default is ˚F. 7.3.6 Factory default setting (P7) Select “Yes” to recover instrument calibration to the theoretical value (pH value in zero potential is 7.00pH, slope is 100%), parameter setting return to initial value.
  • Page 10: Other Specifications

    1-2 years depending on many factors such as frequency of use, nature of test samples, and how well it is maintained, etc. Apera Instruments recommends replacing the pH probe after one year of frequent use to guarantee the optimal performance of a pH meter.
  • Page 11: Troubleshooting Guide

    12 Troubleshooting Guide...
  • Page 12: Warranty

    We warrant this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS (SIX MONTHS for the probe) from the delivery.

This manual is also suitable for:

Premium ph60Premium ph60 seriesPremium ph60fAi312Ai313

Table of Contents