Trane ComfortLink II 4TWV8X24A1000A Installer's Manual page 3

Variable speed heat pumps and air conditioners
Table of Contents

Advertisement

WARNING
400 VOLTS
ELECTRICAL HAZARD
Failure to follow this warning
could result in personal
injury or death.
WAIT TWO (2) MINUTES
after disconnecting power
prior to touching electrical
components as they may
hold a dangerous charge of
400VDC, then verify DC
Voltage is less than 42 VDC at
inverter test points labeled
+VDC and -VDC before
servicing board.
+VDC
Approved Combinations for Variable Speed Units running in
Link mode
UX360 Smart Thermostat
SC360 System Controller
Approved System Accessories
TAMX
S8V2xxxxxxVC
Approved Combinations for Variable Speed Units running in
clii mode
TCONT850, TZONE950, or TZON1050
TAM9
TAM8C
TAM8
S9V2 Furnace w/Relay Panel
XC80 Furnace
XC95m Furnace
Approved System Accessories
Note: See AHRI directory for approved indoor and outdoor model
combinations. Only Trane / American Standard coils and air
handlers are approved for use with variable speed outdoor unit.
Table 1. Operating Range
Cooling
Heating
18-BC106D1-1C-EN
-VDC
55° F to 120° F
-10° F to 66° F
+VDC and
-VDC
Important: Use caution when cleaning outdoor coil to ensure no
water enters the electrical control compartment. When
cleaning coil from inside the compressor compartment,
take special care not to spray water towards the top rows
of the coil near the control panel. Water may enter the
control compartment and drive damaging the
electronics. Disconnect all electric power, including
remote disconnects before servicing.