Leave this Connection Diagram with end user.

MATCH LIT SYSTEM CONNECTION DIAGRAMS

60K - 249K BTU Systems
60K - 120K
FLKV12 (Follow steps 1 - 6)
121K - 249K
FLKV34FIT180 (Follow steps 1 - 6, including 3A)
1. Locate FLKV12 (or FLKV34FIT180)
Parts include Whistle-Free Flex Line, key valve, escutcheon
plate, keys, and FIT180 (FLKV34FIT180 ONLY)
STEP 1 - FIT180
3" Key
Escutcheon
Key Valve
(FLKV12 and FLKV34FIT180)
Thread
sealant is
applied
to this
end only
throughout
instructions
Flared Fitting
3. Connect to Coupling
(FLKV12) Connect one of your ½"
Flared Fittings removed in Step 2
to the ½" coupling located on the
bottom of the aluminum plate with
Apply thread
sealant here
Plate
10
12" Key
FIT180 Kit: ½" x 2" Nipple
Included with FLKV34FIT180 ONLY
Flared End
Coupling
½" Flared Fitting
www.Warming-Trends.com | 303 346 2224 | orders@warming-trends.com
Whistle-Free Flex Line
3A. Connect to FIT180, then to Coupling
(FLKV34FIT180) Connect one ¾" Flared Fitting removed
STEP 3
Use inside threads
of Flared Fitting
FIT180
Apply thread sealant here
Then, connect
into the coupling
located on the
bottom of the
Apply thread
aluminum plate.
sealant here
Tighten.
Flared
Fitting
Whistle-Free Flex Line
¾" Flared Fitting
Coupling
FIT180
Plate
¾" Flared
Fitting