DDP coil inspection and disposal

1. Check the resistance of the coil with a multimeter.
At 20°C, the resistance should be around 0.67 – 0.76 Ohms.
2. If there is evidence of short circuit, then dispose the coil according to local regulations or send back to
Danfoss.
There is no integrated circuit or electronics in the coil.

DDP coil installation

1. Install the coil (K600) with the connector pointing in the same orientation as before.
2. Use a new nylon patched M5x12 screw (K700).
3. Using a 3 mm hex key, fasten the coil with the M5x12 screw in the central hole to the coil core and
torque within the value range specified in the
4. Connect the loose cable of the coil harness (J001 or J002) to the MCON connector of the coil replaced.
A click should be heard if properly inserted.
Fasteners and
torque.