Download Print this page
CAMDEN CM-336 Installation Instructions

CAMDEN CM-336 Installation Instructions

Battery operated active infra-red “hands-free” switches

Advertisement

Quick Links

D o o r Ac t iv a ti o n D e v i c e s
CM-336
Battery Operated Active Infra-Red "Hands-Free" Switche
INSTALLATION INSTRUCTIONS
1. GENERAL DESCRIPTION
Sure-Wave™ Hands-Free switches are active infra-red devices
utilizing micro burst sensor technology, designed for use in
ADA compliant automatic door control applications. These
switches eliminate the spread of germs by avoiding physical
contact and offer building occupants greater convenience
when moving through the premises. Sure-Wave™ switches
are available with either stainless steel or impact resistant
polycarbonate faceplates, in narrow (jamb), single gang or
double gang configurations. All models are ROHS compliant
with lead-free construction.
2. APPLICATION
Sure-Wave™ battery powered hands-free switches are
American Disability Act (ADA) compliant, and provide
barrier free access and egress to buildings and washroom
facilities. Their rugged construction makes them ideal for
use on low-energy automatic doors, drive-up windows, and
interior and exterior doors in virtually any commercial (office,
retail), institutional (school, hospital or clinic), or industrial
(manufacturing) facility.
Three standard face plate widths are available:
CM-336: 2 ¾" x 4 ½" polycarbonate or stainless steel, fits on
single gang electrical boxes.
CM-336/N: 1 ¾" x 4 ½" polycarbonate or stainless steel.
CM-336/W: 4 ½" x 4 ½" polycarbonate or stainless steel, fits on
single gang, double gang or 4 x 4 electrical boxes.
All faceplates may be ordered up with a plain face, with the
waving hand symbol (/40), with the waving hand symbol and
words: WAVE TO OPEN (/41) or with the waving hand, and
wheelchair icons plus words: WAVE TO OPEN (/42).
3. INSTALLATION
Mounting
Sure-Wave™ may be mounted in door jambs, single or double
gang electrical boxes, and 4 x 4 boxes.
NOTE: The sealing gasket (included) is recommended for
outdoor or wet locations. If using with Automatic doors install
in accordance with ANSI A156.10 / A156.19. Select from one of
the following three mounting subsections:
SINGLE GANG ELECTRICAL BOX: CM-336
1a - If using an in-wall box ensure the box is plumb and
square, and flush with the wall surface. (See Diagram 1)
1b - If using a surface box, ensure it is secure & plumb.
2 - Using the dip switch located on the end of the unit, set the
operating mode. (See Section 4)
3 - Attach the unit to the enclosure using the two #6-32 screws
provided.
4 - Attach the faceplate to the unit using the two black
#6-32 x 3/8 machine screws or tamperproof screws.
Do not overtighten!!
s
Page 1 of 4

Advertisement

loading

Summary of Contents for CAMDEN CM-336

  • Page 1 (manufacturing) facility. the following three mounting subsections: Three standard face plate widths are available: CM-336: 2 ¾” x 4 ½” polycarbonate or stainless steel, fits on SINGLE GANG ELECTRICAL BOX: CM-336 single gang electrical boxes. 1a - If using an in-wall box ensure the box is plumb and CM-336/N: 1 ¾”...
  • Page 2 Lazerpoint RF technology and is for use with Camden CM- RX90 V2, CM-RX91 or CM-RX92 Lazerpoint receivers. To pair the CM-336 transmitter to a receiver, press the PB1 (or PB2 on the CM-RX92) button on the receiver using a small blunt Flush object such as a small blade screwdriver or similar.
  • Page 3 CM-336 BATTERY OPERATED ACTIVE INFRA-RED “HANDS-FREE” SWITCHES INSTA LL AT ION INS T RUCT IONS 4. APPLICATIONS & SET-UP APPLICATIONS See Diagram 3 for the location of the Dip switches. DIP Switch Settings 1 LED Enable DIP Switch 1 2 Sounder enable...
  • Page 4 CM-336 BATTERY OPERATED ACTIVE INFRA-RED “HANDS-FREE” SWITCHES I NS TA L L AT IO N I NST RUCT I ONS 5. SYSTEM INSPECTION INSTRUCTIONS After the Installation and operational check of the system: 1. Place warning label on the door (as per ANSI A156.10 or A156.19 guidelines).