1. GENERAL DESCRIPTION
Sure-Wave™ hands-free" switch is an active infrared device
designed for use with an automatic door operator or other
access control products. Applications include low-energy doors,
drive-up windows, health-care facilities, manufacturing, etc.
The assembly fits in a variety of locations from a 1-3/4" door
frame to a 1-gang or 2-gang electrical box. Various size surface
mounting boxes are also available from Camden.
Three standard face plate widths are available:
CM-324: 2-3/4" x 4-1/2" polycarbonate or stainless steel,
fits on single gang electrical boxes.
CM-324/ N: 1-3/4" x 4-1/2" polycarbonate or stainless steel,
fits 1-3/4" door frames or our CM-23D Jamb box.
CM-324/ W: 4-1/2" x 4-1/2" polycarbonate or stainless steel, fits
on single gang, double gang or 4 x 4 electrical boxes.
All faceplates may be ordered up with a plain face (/1), with the
waving hand symbol (/2), or with the waving hand symbol and
words: WAVE TO OPEN (/3).
2. SPECIFICATIONS
12-24V AC/DC ± 12%
Input Voltage
Pulse (sense) / Toggle
Operating Modes
Operating Temp
-4 to +153 ºF (-20 to +85 ºC)
100,000 Operations @ Rated Capacity
Electrical Life
500,000 Operations @ 1/2 Rated Capacity
50 - 60 mA
Current Draw
100 ms
Response Time
Form 'C' (SPDT)
Relay Output
Normal or Fail-Safe
Output Type
Relay Contact Rating 5 amps @ 30 VDC
1 to 5 seconds
Time Delay
11" 22 AWG Leads
Connections
Automatic Self-charging ID
Security
Infra-Red with Coded Modulated Carrier
Technology
2 x #6-32 MS
Mounting
Jamb, 1-gang and 2-gang
Faceplates
Factory Set to 12" (304mm)
Activation Range
(See Page 4)
Range: 1" – 30" (25.4mm – 762mm)
1" W x 4" L x 1-1/2" D
Dimension
(25.4mm x 101.6mm x 38.1mm)
3. INSTALLATION
MOUNTING
Sure-Wave™ may be mounted in door jambs, single or double
gang electrical boxes, and 4 x 4 boxes.
NOTE: The sealing gasket (included) is recommended for
outdoor or wet locations. If using with Automatic doors
install in accordance with ANSI A156.10 / A156.19.
Select from one of the following three mounting subsections:
SINGLE GANG ELECTRICAL BOX: CM-324
1a. If using an in-wall box, ensure the box is plumb and square,
and flush with the wall surface (See Diagram 1).
1b. If using a surface box, ensure it is secure and plumb.
2. Bring your 4-conductor wire through the back or side of the
enclosure and leave approximately 6" tail for wiring connection.
3. Make the electrical connections to the device according to
the wiring section (following).
4. Using the dip switch located on the end of the unit, set the
operating mode (See Section 4) .
5. Attach the unit to the enclosure using the two #6-32
screws provided.
6. Apply power and adjust range and time delay via the
potentiometers on the front of the unit
(See Section 4 for adjustments).
7. Attach the faceplate to the unit using the two black
#6-32 x 3/8 machine screws or tamper-proof screws.
NOTE: Do not overtighten
Page 1 of 4

Advertisement

loading

Summary of Contents for CAMDEN CM 324 Series

  • Page 1 1-gang or 2-gang electrical box. Various size surface Dimension (25.4mm x 101.6mm x 38.1mm) mounting boxes are also available from Camden. Three standard face plate widths are available: 3. INSTALLATION CM-324: 2-3/4” x 4-1/2” polycarbonate or stainless steel, fits on single gang electrical boxes.
  • Page 2 CM-324 ACTIVE INFRARED “HANDS-FREE” SWITCH I NS TA L L AT IO N I NST RUCT I ONS Diagram 1 - Proper Box Installation DOOR FRAME: CM-324N 1a. If mounting directly in a 1” wide aluminum jamb, make a cutout in the door frame at the intended location as per Diagram 2.
  • Page 3 (adjustable timer is inactive in this mode). Switch 3 – LED On/LED Off Camden Door Controls guarantees the Sure-Wave™ to be free from manufacturing defects for 3 years from date of sale. This switch disables the LED, should this feature be desired.
  • Page 4 CM-120i/CM-120wV2 VER. 3 DIGITAL KEYPADS INSTA L L AT I O N I NST RU CTI ONS Diagram 4a - Jamb Cutout Dimensions Diagram 4b - Adjustable Range Settings 1-1/2” (38mm) 1” (25.4mm) 30” (762mm) 3-9/32” 2-7/8” (83mm) (73mm) 0’ 1’...

This manual is also suitable for:

Cm-324nCm-324w