Download Print this page

CAMDEN CM-30E Installation Instructions

Exit switch

Advertisement

Quick Links

Electrified Locks, Relays and Timers
CM-30E
Exit Switch
INSTALLATION INSTRUCTIONS
THIS PACKAGE INCLUDES:
1 x Exit Switch
1 x Plain Ziploc Bag
1 x 6" Black Wire Female Flag Connector
1 x 6" Red Wire Harness
1. GENERAL DESCRIPTION
Camden CM-30 series illuminated Exit switches are designed to
mount into a deep style single gang electrical box. The large 2" square
translucent button is easy to push. One momentary micro switch is
provided with Form C output, rated at 10 amps@125 VAC. CM-30E
supplied with a 12V DC long-life LED.
2. SPECIFICATION
Models
CM-30E
Lens Color
Green Lens
Legend
"Push to Exit"
Size
4.5"H x 2.75"W x 2"D
Mounting
2 x #6-32 machine screws
Switch Rating
10 Amps @ 125 VAC
LED Models
100,000 hours
Voltage Required
12 V or 24 V DC ONLY
NOTES:
If CM-30E will be used with 24V DC, the supplied in-line resistor, must
not be removed.
IMPORTANT:
Leave resistor on for 24 Volts,
Cut off resistor for 12 Volts
Opening New Doors to
Innovation, Quality and Support!
1 x 6" Orange Wire Female Flag Connector
1 x 6" Blue Wire Female Flag Connector
1 x 6" Grey Wire Female Flag Connector
2 x 6-32 x 3/4" Phillips Oval Head Screws
3. MOUNTING
1. Push the color-coded leads onto the switch terminals (if not already
installed), as per the enclosed diagram. If illumination is not required,
the Red & Black wires can be removed.
2. Connect the appropriate wires to your devices. Tuck wiring into box,
and fasten switch plate using screws provided.
4. WARRANTY
Camden Door Controls guarantees the CM-30 to be free from
manufacturing defects for 3 years from date of sale. If during the first
3 years the CM-30 fails to perform correctly, it may be returned to our
factory where it will be repaired or replaced (at our discretion) without
charge. There is no warranty for LED damage due to over voltage!
Except as stated herein, Camden extends no warranties expressed or
implied regarding function, performance or service.
Call: 1.877.226.3369 / 905.366.3377
Visit: www.camdencontrols.com
5 x Grey Plastic Wire Nut
2 x 6-32-3/4" Snake Eye Tamper Proof Screws
1 x Key for Snake Eye Tamper Proof Screws
1 x Installation Manual
File: CM-30E_Manual.indd
Rev.: Nov 06, 2023
Part No.: 40-82B086
Page 1 of 2

Advertisement

loading

Summary of Contents for CAMDEN CM-30E

  • Page 1 100,000 hours Voltage Required 12 V or 24 V DC ONLY NOTES: If CM-30E will be used with 24V DC, the supplied in-line resistor, must not be removed. IMPORTANT: Leave resistor on for 24 Volts, Cut off resistor for 12 Volts File: CM-30E_Manual.indd...
  • Page 2 Page 2 of 2...