4. APPLICATIONS & SET-UP APPLICATIONS
See Diagram 3 for the location of the Dip switches.
DIP Switch Settings
DIP Switch 1
CM-336
1
LED Enable
Green LED flashes while the output is activated
2
Audio Enable
Piezo buzzer sounds when the output is activated
3
Not Used
4
Not Used
Switch 1 – LED On/LED Off
This switch disables the LED, should this feature be desired.
Factory setting is OFF. This feature will decrease the battery
life if set to ON.
Switch 2 – Audio Enable
Set this switch ON to enable an audible beep every time
the switch is activated. Factory default is OFF. Enabling this
feature will use additional power and decrease the life of the
battery.
CM-336 BATTERY OPERATED ACTIVE INFRA-RED "HANDS-FREE" SWITCHES
Description
1 LED Enable
1
2 Sounder enable
2
3 Not used
3
4 Not used
4
Error/
Alarm LED
Range Adj
Diagram 3
Battery Strength Meter
To check the battery strength, place an object in front of
the Surewave™ switch for approximately 5 seconds. The
Surewave™ switch will beep up to 5 times indicating the
battery charge level. 5 beeps being fully charged. 1-3 beeps
indicates you should change the batteries.
Adjustments
Once the Dip switches have been set, and the unit is installed
in the frame or enclosure, apply power to the unit and
observe operation.
Set both potentiometers to minimum setting initially
(fully counter-clockwise).
Adjust the range potentiometer by turning the pot in a
clockwise manner, and passing your hand in front of the unit.
Rotate the pot until the desired range is obtained.
See Diagram 3 for locations.