Product
Maximum Operating
Pressure
Valve Body
Permissible Ambient
Temperature
Conduit Connection
Replacement
Electrical Rating
Recommended
Thermocouple Lead
Lengths
Wiring Connections
Inlet Body Connection
Outlet Body Connection
Types of Gas
Packaging
Bulk Pack Quantity
Bulk Pack Weight
Agency Listing
Specification Standards
Performance specifications are nominal and conform to acceptable industry standards. All agency certification of BASO products is performed
under dry and controlled indoor environmental conditions. Use of BASO products beyond these conditions is not recommended and may void
the warranty. Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh environments. The original
equipment manufacturer or end user is responsible for the correct application of BASO products. Consult BASO Gas Products LLC for
questionable applications. BASO Gas Products LLC shall not be liable for damages or product malfunctions resulting from misapplication or
misuse of its products.
Refer to the G92 Series BASOTROL Automatic Pilot Gas Valve Product Bulletin (BASO-PB-G92) for necessary information on operating and
performance specifications of this product.
450 East Horseshoe Road
PO Box 170
Watertown, WI 53094
1-877-227-6427 (1-877-BASOGAS)
©
2018 BASO Gas Products
Part No. BASO-INS-G92MODELREVB, Rev. -
G92 Model Rev. B Series BASOTROL Automatic Pilot Gas Valve
0.5 psi (35 mbar)
Aluminum
G92_ _ A and G92 _ _ C models without pilot adjust valve
CSA:
-30 to 175ºF (-34 to 79ºC)
UL:
-30 to 125ºF (-34 to 52ºC)
G92_ _ B models with pilot adjust valve
CSA:
32 to 175ºF (0 to 79ºC)
UL:
32 to 125ºF (0 to 52ºC)
SVC200 replaces wire leads
SVC210 replaces conduit connector
12 VDC, 0.025 A (CSA only)
25 VAC, 50/60 Hz, 0.42 A
120 VAC, 50/60 Hz, 0.088 A
240 VAC, 50/60 Hz, 0.044
K15: 12 to 48 in. (305 to 1,220 mm)
K16: 12 to 72 in. (305 to 1,830 mm)
K17: 18 to 72 in. (457 to 1,830 mm)
K19: 18 to 72 in. (457 to 1,830 mm)
1/4 in. (6.35 mm) male quick-connect terminals
1/2 in. NPT
1/2 or 3/4 in. NPT
Natural, Liquefied Petroleum (LP), and LP gas-air mixtures
Bulk pack supplied to original equipment manufacturer (individual pack optional)
32
48 lb (22 kg)
CSA Certificate Number 229521-1656050 (exclude G92CS_)
UL File Number MH2926 (excludes G92CV_ and G92D_ _)
ANSI Z21.78, CSA 6.20
UL Standard 372 and 429
G92 Model Rev. B Series BASOTROL® Automatic Pilot Gas Valve
www.baso.com