Operation Mode - Daikin R32 Split Series User Reference Manual

Domestic hot water tank
Hide thumbs Also See for R32 Split Series:
Table of Contents

Advertisement

5.10 Operation mode

EKHWET90~120BAV3
R32 Split series – Domestic hot water tank
4P680076-1 – 2021.11
2 Select which month to set.
Priority schedule
January
February
March
3 Select the priority schedule of that month.
Priority schedule
January
February
March
Example of possible outcomes based on scheduled Priority schedule are as
follow:
If ...
Which is
A/C request is
priority?
...
DHW
Cooling
Heating
A/C
Cooling
Heating
(a)
Applicable if DHW and A/C requests happen at the same time, when outdoor ambient
temperature and tank target temperature are within operation range of outdoor unit.
(b)
Decided by outdoor unit.
INFORMATION
If the booster heater always takes over the DHW heat load due to setting Priority
schedule to A/C, electricity consumption will be considerably higher. For the
months where A/C heating/cooling is less important, it is recommended to set the
Priority schedule to DHW.
INFORMATION
If DHW is set as priority and frequent DHW operation is expected, there is risk for
comfort problem due to interruption of A/C operation. For the months where A/C
heating/cooling is more important, it is recommended to set the Priority
schedule to A/C.
Choosing Operation mode for DHW
Depending on whether early booster heater operation is desired, two DHW
operation modes can be chosen as follows:
DHW
DHW
DHW
DHW
A/C
DHW
Then heat pump operation = ...
Can
outdoor
unit do
(b)
both?
-
DHW, while A/C is put on hold
Yes
DHW and A/C together
No
DHW, while A/C is put on hold
-
A/C, while DHW is by booster heater
Yes
DHW and A/C together
No
A/C, while DHW is by booster heater
5
Operation
|
(a)
User reference guide
35