Ariston NIMBUS 40 M EXT Technical Instructions page 99

Table of Contents

Advertisement

Available languages

Available languages

DESCRIPTION
12
16
EM Diagnostics - 1 Input
12
16
0
Energy Manager Status
12
16
1
CH Flow Set T
12
16
2
CH Flow Temperature
12
16
4
DHW Storage Temperature
12
16
5
Pressure Switch
12
16
6
HV Input 1
12
16
7
HV Input 2
12
16
8
HV Input 3
12
16
9
AUX Input 1
12
17
EM Diagnostics - 2 Output
12
17
0
CH Circulator Status
12
17
1
HC Pump 2
12
17
2
Diverter Valve (CH/DHW)
12
17
3
Diverter Valve 2 (CH/Cooling)
12
17
4
EM Anode
12
17
5
AUX Output 1 (AFR)
12
17
6
AUX Output 2
12
18
Error History
12
18
0
Last 10 Errors
12
18
1
Reset Error List
12
19
Reset Menu
12
19
0
Reset Factory Settings Boiler
19
Connectivity
19
0
Connectivity Settings
19
0
0
ON/OFF Wi-Fi Network
19
0
1
Network configuration
19
0
3
Internet Time
19
1
Connectivity Info
RANGE
Stand-by
Antifreeze Cycle
Heating Cycle
Heating Temp. Reached
DHW Cycle
Thermal Cleanse Function
Air Purge Function
Chimney Function
Floor drying cycle
No Heat Generation
Manual Mode
Error
Initialization
Off
Cool Mode
DHW Antifreeze
Photovoltaic Integration
Dehumidification
Pump Down
Defrost
Buffer Heating + DHW Serving
Buffer Cooling + DHW Serving
Open - Closed
OFF - ON
OFF - ON
Open - Closed
OFF - ON
OFF - ON
DHW
CH
CH
COOLING
Not active
Active
Open - Closed
Open - Closed
Reset? OK=Yes, esc=No
FACTORY SETTINGS
only reading
only reading (°C)
only reading (°C)
only reading (°C)
only reading (bar)
only reading
only reading
only reading
only reading
only reading
only reading
only reading
only reading
only reading
/ 99