INSTALLATION GUIDE

Warning
The appliance must be installed by a qualified technician in
possession of the skills required by law.

Before installing the appliance

• The outdoor unit uses an ecological refrigerant liquid (type
HFC R-410A) that does not affect the integrity of the ozone
layer. Refrigerant R-410A operates at a pressure 50-70%
higher than refrigerant R22. Make sure that all the mate-
rials used for maintenance and to fill the components can
be used with refrigerant R-410A.
• The bottles containing refrigerant R-410A are equipped
with a dip tube which allows the liquid to flow only when
placed in a vertical position with the valve in the upper po-
sition.
• The appliance should be filled with the indicated refrige-
rant R-410A. Apply a dispenser, available on the market, on
the pipe sleeve, in order to vaporize the refrigerant before
it flows in the external unit.
• The refrigerant R-410A, as all HFC fluids, is only compatible
with the oils recommended by the compressor manufac-
ture.
• The vacuum pump is not sufficient to completely eliminate
the presence of humidity in the oil.
• POE type oils quickly absorb humidity. Do not expose oil to
air.
• Never open the appliance when it is in vacuum conditions.
• Do not throw the refrigerant R-410A in the environment.
• Ensure that, during the installation of the external unit, all
national regulations in terms of safety are observed.
• Make sure that the appliance is connected properly to the
ground. Check that the voltage and frequency of power
supply match those necessary to the external unit and that
the installed capacity is sufficient to allow the functioning of
the appliance itself.
• Check that the impedance of the supply net corresponds
to the power input from the external unit as shown on the
data plate of this unit (EN 61000-3-12).
• Check that safety switches are correctly sized and connec-
ted to the external unit.
WARNING:
Define where the units will be located taking into account
the minimum installation clearances in mm shown here
above.
Note: The distances indicated here above are the mini-
mum for a good unit operation. To avoid abnormal noise,
echoes and resonances increase this distances especially
on the front side of the units. The height of the obstacles
at both front and side should be lower than the height of
the outdoor unit.
70 /
Choice of placement
• Avoid a mounting where the ODU is surrounded by walls
• Avoid a mounting in sinks. Cold air sinks down and by that
air short circuit could occur.
• Avoid positioning the external unit in places which are dif-
ficult to access for the subsequent installation and mainte-
nance.
• Avoid placing it near sources of heat.
• Avoid placing it in places where the external unit is subjec-
ted to continuous vibration.
• Do not place the external unit on structures that do not
guarantee support.
• Avoid placing it in close proximity to fuel tanks of gas.
• Avoid a positioning that provides exposure to oil vapors.
• Avoid a positioning characterized by particular environ-
mental conditions.
• Choose a location where noise and air discharged from
the outdoor unit will not disturb the neighbors.
• Choose a position sheltered from the wind.
• Provide a placement that allows the compliance to the re-
quired installation distances.
• Avoid placing it in a location that prevents access to ports
and / or passageways.
• The structure of the soil surface should be able to support
the weight of the external unit and reduce as much as pos-
sible vibrations.
• If the external unit is installed in a location where there are
abundant snowfall, install the unit at least 200 mm above
the usual level of fallen snow or use a support bracket.
• External unit must be installed on antivibration support.
• Install wind barriers if the system is installed in areas subjec
to strong winds.

Minimum distances to installation (mm)

150
300
150
1000