Download Print this page
3onedata NP5000 Series Quick Installation Manual

3onedata NP5000 Series Quick Installation Manual

Serial server

Advertisement

Quick Links

NP5000 Series
Serial Server Quick Installation
Guide
3onedata Co., Ltd.
Address:
3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Xili, Nanshan District, Shenzhen
Website:
www.3onedata.com
Tel:
+86 0755-26702688
Fax:
+86 0755-26703485
【Package Checklist】
Please check whether the package and accessories are intact
while using the device for the first time.
1.
Serial Server
2.
3.
CD
4.
5.
Power adapter
6.
7.
Certification
8.
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
The products are desktop safe serial servers, including the
following models:
Model I. NP5000-1T-1DI(3IN1)-DB-P(12-48VDC) (1 100M
copper port + 1 3IN1 DB9 serial port with isolation +
1 12~48VDC power supply)
Model II. NP5000-1T-2DI(3IN1)-DB-P(12-48VDC) (1 100M
Model III. NP5000-2T-4DI(3IN1)-RJ-P(12-48VDC) (2 100M
Model IV. NP5000-2T-8DI(3IN1)-RJ-P(12-48VDC) (2 100M
【Panel Design】
Model I
Quick installation guide
Model II
Lugs
Straight-through cable
Warranty card
copper port + 2 3IN1 serial ports with isolation + 1
12~48VDC power supply)
copper ports + 4 3IN1 RJ45 serial ports with
isolation + 1 12~48VDC power supply)
copper ports + 8 3IN1 RJ45 serial ports with
isolation + 1 12~48VDC power supply)
Model III
Model IV

Advertisement

loading

Summary of Contents for 3onedata NP5000 Series

  • Page 1 Model II. NP5000-1T-2DI(3IN1)-DB-P(12-48VDC) (1 100M copper port + 2 3IN1 serial ports with isolation + 1 NP5000 Series 12~48VDC power supply) Model III. NP5000-2T-4DI(3IN1)-RJ-P(12-48VDC) (2 100M Serial Server Quick Installation copper ports + 4 3IN1 RJ45 serial ports with Guide isolation + 1 12~48VDC power supply) Model IV.
  • Page 2 moist, keep the relative humidity of the device surrounding between 5%~95% without condensation. Before power on, first confirm the supported power  supply specification to avoid over-voltage damaging the device. The device surface temperature is high after running;  please don't directly contact to avoid scalding. 【Wall-mounted Device Mounting】...
  • Page 3 the wall for reference or refer to the mounting DC power supply input terminal blocks that adopts , in which The Model III and Model IV provide 1 program dimension to mark two screw positions. V+ and V- are DC input, FG is the power grounding input; The debugging port based on RS232 serial port Step 3 Nail M4 screws on the wall and keep 2mm...
  • Page 4 This device supports WEB management and configuration. of network port 1 of model III and model IV is Computer can access the device via Ethernet interface. The "192.168.1.254", and the default IP address of network way of logging in to device’s configuration interface via IE port 2 is "192.168.8.254".

This manual is also suitable for:

Np5000-1t-1di(3in1)-db-pNp5000-1t-2di(3in1)-db-pNp5000-2t-4di(3in1)-rj-pNp5000-2t-8di(3in1)-rj-p