Siemens SIMOTICS S-1FK2 Operating Instructions Manual page 58

Hide thumbs Also See for SIMOTICS S-1FK2:
Table of Contents

Advertisement

Preparing for use
4.2 Transportation and storage
Long-term storage
Note
Storage time up to two years
The storage time affects the properties of the rolling bearing grease.
• Store the motor for up to two years at -15° C to 55° C.
If you store the motor for longer than six months, carefully ensure that the storage facility
complies with the following conditions:
Table 4-2
Climatic ambient conditions
Highest relative humidity
Mechanical ambient conditions
Protection against chemical substances
Biological ambient conditions
Duration
Check the correct state of the motor every six months.
• Check the motor for any damage.
• Perform any necessary maintenance work.
• Check the state of the dehydrating agent and replace when necessary.
• Record the preservation work so that all preservation coating can be removed prior to the
commissioning.
Condensation
The following ambient conditions encourage the formation of condensation:
• Significant ambient temperature fluctuations,
• Direct sunshine,
• High humidity during storage.
Avoid these ambient conditions.
Use a dehydrating agent in the packaging.
56
Ambient conditions for long-term storage in the product packaging according to Class
1K3 to EN 60721‑3‑1 - with the exception of influencing environmental variables "Air
temperature", "Highest relative humidity" and "Condensation"
‑15 °C to +55 °C
< 60%, condensation not permissible
vibration-free storage room v
Protected in acc. with Class 1C2
Suitable in acc. with Class 1B2
• Six months for the above-mentioned condi‐
tions.
• Special preservation measures are required
for storage periods of 6 months up to a
maximum of two years.
SIMOTICS S-1FK2 synchronous motors for SINAMICS S120
Operating Instructions, 02/2022, A5E46089564B AD
< 0.2 mm/s
rms

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1ft2

Table of Contents