Download Print this page
Kohler ODEON K-8766 Installation Instructions Manual
Kohler ODEON K-8766 Installation Instructions Manual

Kohler ODEON K-8766 Installation Instructions Manual

Advertisement

Quick Links

BEFORE YOU BEGIN
Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences. Follow
Ÿ
the sections that pertain to your particular installation. This will help you avoid costly mistakes. In addition to Proper installation,
read all operating and safety instructions.
All information in these instructions is based upon the latest product information available at the time of publication.
Ÿ
Kohler India reserves the right to make changes in product characteristics, packaging, or availability at any time without notice.
These instructions contain important care, cleaning, and warranty information- please leave instructions for the consumer.
Ÿ
ORDERING INFORMATION
Odeon S-Trap 305mm Toilet...............................K-8766LM
Includes seat.................................................K-8827LM
Includes bowl................................................K-8767LM
Includes tank.................................................K-8710LM
NOTES
Observe all local plumbing and building codes.
Ÿ
Shut off the water supply.
Ÿ
Ensure that the new drain and shut-off valve have the correct roughing-in dimensions. See Fig.#1.
Ÿ
Be very careful while working with vitreous china products. Vitreous china can break or chip if the bolts or nuts are overtightened, or
Ÿ
if carelessly handled.
Carefully inspect the new fixture for any sign of damage.
Ÿ
Fixture dimensions are nominal and conform to tolerances established by ASME Standards (A112. 19.2-2003)
Ÿ
TOOLS AND MATERIALS REQUIRED
(Not supplied)
254mm adjustable wrench
Ÿ
Metal file (file cut)
Ÿ
Tape measure
Ÿ
Tubing cutter
Ÿ
WARNING: Risk of external leakage.
1/4 turn past finger tight.
NOTICE:
If no shut-off valve exists, install a shut-off valve below the tank before installing the new toilet.
Flexible hose are recommended to connect the supply line to the fill valve. If you use a rigid connection, take care not to apply side
forces to the bottom of the fill valve.
1037406-LM01-B
Odeon P-Trap 180mmToilet..............................K-8711LM
Level
Screwdriver
Hacksaw
Putty knife
Toilet supply shut-off valve. 15mm (½") recommended
The valve nut has been factory-tightened. Wrench tighten
-1-
INSTALLATION INSTRUCTIONS
VITREOUS CHINA P/S-TRAP TOILET
S-TRAP 305mm K-8766 LM
P-TRAP 180mm K-8711 LM
Includes Seat.............................................K-8827LM
Includes bowl.............................................K-8709LM
Includes tank..............................................K-8710LM
Straight pipe coupling
Connection packaging
ODEON

Advertisement

loading

Summary of Contents for Kohler ODEON K-8766

  • Page 1 All information in these instructions is based upon the latest product information available at the time of publication. Ÿ Kohler India reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. These instructions contain important care, cleaning, and warranty information- please leave instructions for the consumer.
  • Page 2: Installation

    All dimensions in mm. Fixture dimensions are nominal and conform to tolerances as per ASME Standard A112. 19.2M. Ÿ Product pictures shown are representative only, actual products may vary. Ÿ Kohler reserves the right to make changes in product characteristics, packaging or availability at any time without notice. Ÿ INSTALLATION 1. REMOVE EXISTING TOILET Turn off water supply.
  • Page 3 NOTE: Do not use white cement or high lime content cements to install this toilet. The expansion of cement due to a rise in temperature may make the toilet crack or cause damage. Kohler is not responsible for any damage caused by installation with the use of cement.
  • Page 4 Fig. #4a 4 Connect fill valve to water supply with hose only. NOTE: use hose only, length: 200-300mm minimum (Not provided.) 5. CHECK WATER LEVEL Turn on water supply, check for leaks. If necessary, adjust black float adjustment clip, and sliding float up or down on metal float rod until water level at marked level line.
  • Page 5 6. ADJUST OVERFLOW HEIGHT (If necessary) Adjust overflow tube so that the top is 20mm above the waterline. Push locking mechanism to the side and adjust tube height. Push locking mechanism back into position to lock tube height. See Fig. #6. maxi Fig.
  • Page 6: Troubleshooting Chart

    Do not use in-tank cleaners. Products containing chlorine (calcium hypochlorite) can seriously damage fittings in the tank. This damage can cause leakage and property damage. Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine (calcium hypochlorite)
  • Page 7 (This Page is left blank intentionally. 1037406-LM01-B...
  • Page 8 Toll Free : 1800 4KOHLER 1037406-LM01-B...

This manual is also suitable for:

Odeon k-8711