Page 1
OPERATING INSTRUCTIONS Translation of the Original PLUG-IN BOARDS for total pressure measuring and control units TPG 300/TPG 500...
Page 2
Dear Customer, Thank you for choosing a Pfeiffer Vacuum product. Your new total pressure measuring and control unit should support you in your individual application with full performance and without malfunctions. The name Pfeiffer Vacuum stands for high-quality vacuum technology, a comprehensive and complete range of top-quality products and first-class service.
Table of contents Table of contents About this manual Validity 1.1.1 Applicable documents 1.1.2 Variants Target group Conventions 1.3.1 Instructions in the text 1.3.2 Pictographs 1.3.3 Abbreviations Trademark proof Safety General safety information Safety instructions Safety precautions Proper use Foreseeable improper use Product description Function 3.1.1 Pirani measurement system...
Page 4
Operation Calibrating Pirani measuring circuit Malfunctions Shipping Recycling and disposal 10.1 General disposal information 10.2 Disposing of plug-in boards Service solutions by Pfeiffer Vacuum Accessories 12.1 Accessory information 12.2 Ordering accessories Technical data and dimensions 13.1 Technical data 13.2 Dimensions Appendix 14.1 Units of pressure...
Page 5
List of tables List of tables Tbl. 1: Applicable documents Tbl. 2: Variants Tbl. 3: Abbreviations used Tbl. 4: Switch functions on IF 300A/C/P Tbl. 5: Switching functions on IF 300B Tbl. 6: Disturbances during installation Tbl. 7: Interference during operation and calibration Tbl.
Page 6
List of figures List of figures Fig. 1: "OUTPUT" connection with 2 sockets Fig. 2: "CONTROL" connection on PE 300 DC9 Fig. 3: Switch and logic on the "CONTROL" connection Fig. 4: "RELAY" connection on IF 300A/C/P Fig. 5: "RELAY" connection on IF 300B Fig.
IF 300 P PT 441 595-T Interface board (Profinet) IF 500 PN Tbl. 2: Variants You can find the part number on the rating plate of the product. Pfeiffer Vacuum reserves the right to make technical changes without prior notification. 7/50...
About this manual The figures in this document are not to scale. Dimensions are in mm unless stated otherwise. 1.2 Target group These operating instructions are aimed at all persons performing the following activities on the product: ● Transportation ● Setup (Installation) ●...
About this manual Abbreviation Explanation P GND Protective ground Profibus DP Profibus distributed periphery RS-232 Standard for a serial interface often available on computers (Recommended Stand- ard 232) RS-422 Interface standard for a wired differential serial data transfer (Recommended Stand- ard 422) Incoming data line (Received eXchange Data) Received data...
Safety instructions according to product life stages All safety instructions in this document are based on the results of a risk assessment. Pfeiffer Vacuum has taken into account all the relevant life stages of the product. Risks during installation DANGER Danger to life due to dangerous contact voltage Voltages above 30 V (AC) or 60 V (DC) are considered dangerous in accordance with EN 61010.
► Provide suitable touch protection, if the surface temperature exceeds 70 °C. ► Inform yourself about any contamination before starting work. 2.4 Proper use The plug-in boards are analog measuring, interface and relay boards for the ModulLine total pressure measuring and control units TPG 300 and TPG 500. 11/50...
Safety ► Install, operate and maintain the product only in accordance with these operating instructions. ► Comply with the limits of use. ► Observe the technical data. 2.5 Foreseeable improper use Improper use of the product invalidates all warranty and liability claims. Any use that is counter to the purpose of the product, whether intentional or unintentional, is regarded as improper use;...
3.2 Identifying the product You will need all the data from the rating plate to safely identify the product when communicating with Pfeiffer Vacuum. 1. Read the data on the product rating plate. 2. Record this data.
Product description and CP 300 T11L) have special electronics that limit the measurement current to 100 μA. This results in a considerably longer service life for the gauges. Pirani/cold cathode measurement boards have: ● 1 Pirani measuring circuit with ─ 1 gauge power supply plug ─...
Product description 4, 5 4, 5 Fig. 3: Switch and logic on the "CONTROL" connection 3.4.3 "RELAY" connection on IF 300A/C/P Screen Fig. 4: "RELAY" connection on IF 300A/C/P The figure shows the contacts in rest position. Pins Designation Switching function Relay 1 Relay 2 Relay 3...
Product description The figure shows the contacts in rest position. Pins Designation Switching function Relay 1 Relay 2 Relay 3 Relay 4 Relay 5 Error status Tbl. 5: Switching functions on IF 300B 3.4.5 "RS-232" connection on IF 300A IF 300 A S GND S GND Screen...
Product description 3.4.7 "RS-422" connection on IF 300C IF 300 C P GND S GND RX– TX– Screen Fig. 8: "RS-422" connection on IF 300C Protective ground (P GND) Reception data (Rx-) (relating to the measuring device) 2, 3, 4 unassigned Transmission data (Tx+) (relating to the measuring device) Signal ground (S GND)
Product description IF 300 P Fig. 9: "Profibus" connection on IF 300P 1 Screen VP (only required with bus end devices) 2 Do not connect Do not connect 3 RxD/TxD-P (Line B) RxD/TxD-N (Line A) 4 CNTR-P (optional) Do not connect 5 DGND 3.4.9 "Profinet"...
Product description 3.5 Scope of delivery The scope of delivery includes the following parts: ● Plug-in board ● Plugs for analog signals ● Folding ferrite (for IF 300B) ● Operating instructions Unpacking the product and checking completeness of the shipment 1. Unpack the product. 2.
Transport and storage 4 Transport and storage 4.1 Transporting product NOTICE Damage caused by incorrect transport Transport in unsuitable packaging or failure to install all transport locks can result in damage to the product. ► Comply with the instructions for safe transport. NOTICE Damage to unit from electrostatic discharge Electrostatic discharge damages electronic components.
Page 21
Transport and storage ► Seal connections with the original protective caps. ► Protect the product with the original transport protection (where available). 21/50...
Installation 5 Installation 5.1 Installing/removing plug-in boards NOTICE Damage to unit from electrostatic discharge Electrostatic discharge damages electronic components. Defects resulting from failure to comply with this warning shall result in loss of any warranty claim entitlement. ► Carry out all work on ESD-protected workstations only, in compliance with the appropriate work- ing methods.
Installation Procedure 1. Make sure that the TPG is switched off. 2. Despite being partially screened, do not lay the gauge cable parallel with cables with too much interference. 3. Connect the gauge with the measuring cable to the "IKR" connection on the measurement board. 4.
With voltages < 50 V, you may use 4.8 × 0.8 mm insulated flat pin terminals. However, Pfeiffer Vacuum recommends using the relay plug, as the relay plug enables fast discon- nection of the connection as well as strain relief.
Installation Connecting relays (IF 300B) Screened cable is not required for the connection. 1. Only carry out work on the plug when it is de-energized. 2. In general, use the relay plug for voltages ≥ 50 V for safety reasons. 3.
Installation 4. Make sure that components to be connected externally contain the technical data of the plug-in board. 5. Use a suitable interface cable to connect the interface. 5.3.6 Connecting "Profibus-DP" interface of IF 300 P Details on the Profibus-DP interface You can find details on the Profibus-DP interface in the corresponding communication pro- tocol.
Operation 6 Operation Switching measuring circuit on or off externally (PE 300 DC9) ► First switch the gauge on manually or automatically if you want to control the gauge via the exter- nal input. ► Switch the measuring circuit on or off using one of the three options. ●...
Pirani measuring circuit. A zero point shift will necessitate recalibration or cleaning. Pfeiffer Vacuum has calibrated the gauge to standard values at the factory. However, as a result of indi- vidual scattering, gauge tolerances, gauge contamination or different cable lengths, you must accept deviations.
Malfunctions 8 Malfunctions Warranty Malfunctioning of the equipment as a direct result of contamination or wear, as well as wear parts, is not covered by the warranty. Malfunction Possible cause Remedy Gauge cable will not connect to IKR gauge. Old IKR gauge with MHV Use a correct cable.
Page 30
Check the firmware: ● TPG 300 firmware: not supported ● TPG 500 firmware: V010300 ● Profinet firmware: V010100 Tbl. 12: Disturbances with the Profinet interface On TPG 300 basic unit, from firmware 302-654. On TPG 300 basic unit, from firmware 302-654. 30/50...
► Comply with the instructions for safe distribution. Decontamination subject to charge Pfeiffer Vacuum decontaminates products not clearly declared "Free of contamination" at your expense. Ship product safely ► Do not ship microbiological, explosive or radioactively contaminated products.
– Fluoroelastomers (FKM) – Potentially contaminated components that come into contact with media 10.2 Disposing of plug-in boards Pfeiffer Vacuum plug-in boards contain materials that you must recycle. 1. Separate the components into recyclable materials. 2. Recycle the components. 3. Dispose of the product or components in a safe manner according to locally applicable regula- tions.
We are always focused on perfecting our core competence – servicing of vacuum components. Once you have purchased a product from Pfeiffer Vacuum, our service is far from over. This is often exactly where service begins. Obviously, in proven Pfeiffer Vacuum quality.
Page 34
Service solutions by Pfeiffer Vacuum 5. Prepare the product for transport in accordance with the provisions in the contamination declaration. a) Neutralize the product with nitrogen or dry air. b) Seal all openings with blind flanges, so that they are airtight.
Measurement cable in standard and high temperature versions in different lengths, for connecting to a Pfeiffer Vacuum total pressure measuring and control unit or an ionization measuring device Dummy plates Cover plate for free slots on Pfeiffer Vacuum total pressure measuring and control units that are not fully configured 12.2 Ordering accessories...
Accessories Measuring and extension cable The cable is available in a standard version for temperatures up to max. 80 °C and as a high temperature table for temperatures up to 250 °C. TPR 010: Amphenol C 091 E Amphenol C 091 E TPR 017/018: LEMO male female...
Technical data and dimensions 13 Technical data and dimensions 13.1 Technical data Parameter Value/designation Measuring board PI 300 D for Pirani gauges with wolfram fil- ament PI 300 DN for Pirani gauges with nickel fila- ment Number of measuring circuits Measuring range (N equivalent) 1000 hPa –...
Page 40
Technical data and dimensions Parameter Value/designation Number of measuring circuits 1 each of Measuring range (N equivalent) Pirani 1000 hPa – 8 × 10 Cold cathode CP 300 C9 5 × 10 hPa – 5 × 10 CP 300 C10 5 ×...
Technical data and dimensions Parameter Value/designation DC characteristics Switching current, max. 0.25 A with 200 V DC 0.3 A with 140 V DC 0.4 A with 100 V DC 0.5 A with 60 V DC 0.6 A with 50 V DC 0.8 A with 40 V DC 4.0 A with 30 V DC Switching output, max.
Technical data and dimensions Parameter Value/designation DC characteristics Switching current, max. Switching voltages > 50 V DC are not permitted for safety reasons. 0.6 A with 50 V DC 0.8 A with 40 V DC 1.5 A with 30 V DC Switching output, max.
Appendix 14.3 Converting measuring signal and pressure p [hPa] TPR 010 / TPR 018 with PI 300 D TPR 017 with PI 300 DN –1 –2 –3 –4 Fig. 21: Relationship between measuring signal and pressure for TPR gauges p Pressure Measuring signal [V] (output voltage) 46/50...
Appendix p [hPa] –8 –9 IKR 050/060 with CP 300 C9 IKR 050/060 with CP 300 C10 –10 IKR 070 with PE 300 T11 IKR 050/060 with PE 300 DC9 –11 Fig. 22: Relationship between measuring signal and pressure for IKR gauges p Pressure Measuring signal [V] (output voltage) 14.4 Gas type dependence...