Approval; Technical Data - Siemens Hicom cordless EM Operating Instructions Manual

Siemens hicom cordless em gigaset active operating instructions
Table of Contents

Advertisement

Appendix

Approval

The mobile units have been approved by the German Fed-
eral Office of Telecommunication Approval (BZT). They
comply with the conditions of approval passed by the Fed-
eral Ministry for Post and Telecommunications (BMPT) for
connection to the Hicom cordless EM telephone system.
They can also be registered and operated on the 10xx and
20xx Gigaset base stations.

Technical data

Standards
No. of channels
Frequencies
Duplex opera-
tion
Channel config-
uration
Bit rate
Modulation
Voice encoding
Transmit power
Range
Convenience mobile unit
Battery life
Permitted envi-
ronmental condi-
tions for
operation*
Weight incl. bat-
teries
Dimensions
(L x B x H)
* In non-protected environments
DECT in accordance with
ETSI, CTR 6, CTR 10, GAP
Ex protection in accordance with
EN 50014 and EN 50020
120 duplex channels
1.88 GHz to 1.90 GHz
Time duplex with
10 ms frame length each
1728 kHz
1152 kbit / s
GFSK
32 kBit/s (ADPCM)
10 mW medium power;
250 mW peak power
outdoors
indoors
see "Charging and using the batteries"
page 16
-10 °C to +40 °C
100% relative air humidity
as well as water splashes and jets
(IP 65)
approx. 165 g
approx. 160 x 55 x 25 mm
61
approx.300 m
approx.50 m