Pagepac plus zone expansion unit

Advertisement

Quick Links

PagePac
by
INTRODUCTION
The Zone Expansion Unit (Z.E.U.) connects up to
16 zones of audio output (including talkback),
contact closure outputs or inputs.
SPECIFICATIONS
FEATURES
• Provides same features as PP+ Controller
• Maximum of 3 Z.E.U.s per Controller
Power Requirements
• Power from the PP+ Controller through the
interconnect cable
Dimensions/Weight
• 16.00"W x 1.75"H x 6.875"D
(40.64cm x 4.45cm x 17.46cm)
• 3.0 lbs (1.35 kg)
Environment
• Temperature:0 to 40°C (32 to 104°F)
• Humidity:
Locate in an area free of excess moisture, corro-
sive gases, dust and chemicals.
INSTALLATION
MOUNTING
NOTE: When installing the Zone Expansion Unit,
leave at least four inches of space above and
below for proper ventilation.
Installing the paging equipment in a ventilated
room where there is easy access to speaker
cabling (preferably in the telephone equipment
room). Disconnect all power before installing
equipment.
1. Mount the Zone Expansion Unit(s)(Z.E.U.) to
either a wall, cabinet or a rack (below the con-
troller).
Technical Manuals Online! - http://www.tech-man.com
Technical Manuals Online! - http://www.tech-man.com
®
PAGEPAC PLUS ZONE EXPANSION UNIT
(see Table 2)
5 to 95%
firealarmresources.com
V-5335100
2. Connect 8-pin Molex from Controller to first
Z.E.U., and next Z.E.U's, if used.
NOTE: Up to 3 Z.E.U.s can be used, providing up
to 56 paging and/or control zones.
3. Set DIP switches on each Z.E.U.(s).
4. Set the Zone Option switches on the
Controller and Z.E.U.(s).
NOTE: For each zone used, no matter what its
function, this switch needs to be set to one of
three settings for proper zone operation before
applying power to the system.
The Controller has eight switches for zones 1-8.
Each subsequent Z.E.U. has switches for zones
9-24, 25-40, 41-56.
Refer to the Zone Map and Zone Configuration
Tables filled out during facility paging system
design. You can find these in the PagePac® Sys-
tem Installation and Configuration Guide.
5. Locate and mount all speakers in accordance
with the floor plan drawing for this installation.
6. Connect each speaker to the appropriate
Home Run or Speaker-to-Speaker wiring
scheme as shown on the floor plan.
NOTE: Adjust all speakers per volume and power
requirements as noted on floor plan, during or
after installation. Figures 7 and 8 show wiring
methods using local and zone connector blocks,
and contact closure zone applications.
1
Issue 1
947187

Advertisement

loading

Summary of Contents for Valcom PagePac V-5335100

  • Page 1 ® PagePac Issue 1 PAGEPAC PLUS ZONE EXPANSION UNIT V-5335100 INTRODUCTION The Zone Expansion Unit (Z.E.U.) connects up to 16 zones of audio output (including talkback), contact closure outputs or inputs. SPECIFICATIONS (see Table 2) FEATURES • Provides same features as PP+ Controller 2.
  • Page 2: Troubleshooting

    TROUBLESHOOTING 7. Test speaker wiring for short circuits. Measure the resistance of each Home Run wiring Some common problems encountered when the with an ohmmeter. Any pair indicating a value of paging system is not operating are described less than 15 Ohms must be rechecked for possi- below.
  • Page 3: Technical Assistance

    Call (540) the problem. Send the unit to: 427-3900 and ask for PagePac Technical Sup- port, or call (540) 427-6000 for Valcom 24-hour ® PagePac Repair Dept.
  • Page 4 FRONT DETAIL PagePac Plus  PagePac Plus  AmpliCenter D300 Am pliC enter D 30 0 PagePac Plus PO WE R  Con tro ller Call Stac ker PagePac Plus  POWER 4.0" Controller TYPICAL Call Stacker COMBINATION PAN HEAD 19'' PILOT POINT # 12 - 24 (TYPICAL)
  • Page 5 Figure 4. Setting Zone Expansion Unit Dip Switches Figure 5. Setting Zone Option Switches on Controller and Zone Expansion Units 947187 Technical Manuals Online! - http://www.tech-man.com Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 6 Figure 6. Speaker Wiring Methods Figure 7. Zone Wiring Using Connector Blocks 947187 Technical Manuals Online! - http://www.tech-man.com Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 7 INPUT CONTACT CLOSURE Figure 8. Speaker and Contact Closure Zone Wiring to Controller Figure 9. Zone Expansion Unit Back Panel 947187 Technical Manuals Online! - http://www.tech-man.com Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...