PAGEPAC PLUS ZONE EXPANSION UNIT
INTRODUCTION
The Zone Expansion Unit (ZEU) provides up to
16 zones of audio output (including talkback),
contact closure outputs or inputs.
SPECIFICATIONS
FEATURES
• Provides same features as PagePac Plus
Controller
• Maximum of 3 ZEUs per Controller

Power Requirements

• Power from the PagePac Plus Controller
through the interconnect cable
Dimensions/Weight
• 16.00"W x 1.75"H x 6.88"D
(40.64cm x 4.45cm x 17.48cm)
• 3.0 lbs (1.36 kg)
Environment
• Temperature
0 to +40° C (+32 to +104° F)
• Humidity:
5 to 95% (non-condensing)
Locate in an area free of excess moisture,
corrosive gases, dust and chemicals.
INSTALLATION
MOUNTING
NOTE: When installing the Zone Expansion
Unit, leave at least four inches of space above
and below for proper ventilation.
Installing the paging equipment in a ventilated
room where there is easy access to speaker
cabling (preferably in the telephone equipment
room). Disconnect all power before installing
equipment.
®
V-5335100
(see Table 2)
1. Mount the Zone Expansion Unit(s) (ZEU) to
either a wall, cabinet or a rack (below the
controller).
2. Connect 8-pin Molex from Controller to first
ZEU, and next ZEUs, if used.
NOTE: Up to 3 ZEUs can be used, providing
up to 56 paging and/or control zones.
3. Set DIP switches on each ZEU(s).
4. Set the Zone Option switches on the
Controller and ZEU(s).
NOTE: For each zone used, no matter what
its function, this switch needs to be set to one
of three settings for proper zone operation
before applying power to the system.
The Controller has eight switches for zones 1-8.
Each subsequent ZEU has switches for zones
9-24, 25-40 and 41-56.
Refer to the Zone Map and Zone Configuration
Tables filled out during facility paging system
design. You can find these in the PagePac®
System Installation and Configuration Guide.
5. Locate and mount all speakers in accordance
with the floor plan drawing for this
installation.
6. Connect each speaker to the appropriate
Home Run or Speaker-to-Speaker wiring
scheme as shown on the floor plan.
NOTE: Adjust all speakers per volume and
power requirements as noted on floor plan,
during or after installation.
1
Issue 3
947187

Advertisement

Table of Contents
loading

Summary of Contents for Valcom V-5335100

  • Page 1: Power Requirements

    PagePac ® Issue 3 PAGEPAC PLUS ZONE EXPANSION UNIT V-5335100 INTRODUCTION The Zone Expansion Unit (ZEU) provides up to 16 zones of audio output (including talkback), contact closure outputs or inputs. SPECIFICATIONS (see Table 2) 1. Mount the Zone Expansion Unit(s) (ZEU) to...
  • Page 2: Powering Up System

    Figures 7 and 8 show wiring methods using 2. Begin programming the Controller. local and zone connector blocks, and contact A quick reference card for telephone closure zone applications. programming, along with detailed programming instructions, can be found in the PagePac Plus 7.
  • Page 3: Technical Assistance

    563-2000 and press 1 for PagePac Technical Valcom, Inc. Support or visit our websites at ® PagePac Repair Dept. http://www.pagepac.com and www.valcom.com. 5614 Hollins Road Roanoke, VA 24019-5056 Table 2. ZEU Specifications Capacities Each ZEU connects up to 16 zones of audio output (including talkback), contact closure outputs or inputs.
  • Page 4 FRONT DETAIL PagePac Plus  AmpliCenter D300 PagePac Plus  AmpliCenter D300 PagePac Plus  POWER Controller Call Stacker PagePac Plus  POWER 4.0" Controller TYPICAL Call Stacker COMBINATION PAN HEAD 19'' PILOT POINT # 12 - 24 (TYPICAL) REAR DETAIL ZONE WIRING TEL LINE...
  • Page 5 Figure 4. Setting Zone Expansion Unit Dip Switches Figure 5. Setting Zone Option Switches on Controller and Zone Expansion Units...
  • Page 6 Figure 6. Speaker Wiring Methods Figure 7. Zone Wiring Using Connector Blocks...
  • Page 7 INPUT CONTACT CLOSURE Figure 8. Speaker and Contact Closure Zone Wiring to Controller Figure 9. Zone Expansion Unit Back Panel...
  • Page 8 VALCOM LIMITED WARRANTY Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service for a period of one year from the date of shipment. The obligation under this warranty shall be limited to the replacement, repair or refund of any such defective device within the warranty period, provided that: inspection by Valcom, Inc.

This manual is also suitable for:

Pagepac plus v-5335100

Table of Contents