Valcom VL-9998RM Manual
Valcom VL-9998RM Manual

Valcom VL-9998RM Manual

Supervised idf

Advertisement

Quick Links

Introduction

These instructions contain the specifications
and guidelines necessary to install, operate,
and maintain the VL-9998RM Rack Mount and
VL-9998WM Wall Mount Supervised IDF.
The VL-9998RM and VL-9998WM provide
audio, 24VDC and wire monitoring for up to 12
supervised self amplified speaker runs in a
single zone configuration, or may be
configured for 2 paging zones with 6 speaker
runs in each zone. Up to (6) 1 watt interior
speakers may be connected to each output or
(1) 5 Watt Paging horn. Consult Valcom
Services LLC for other configurations.
The unit provides both audible and visual
indication of wire faults

Features

Red Alarm Led
Power Indicators (Green)
Pushbutton Switch (Fault Silence)
Individual Speaker Line Status Indicators
(Red Led's)
Bypass Selection for Each Output
Buzzer for Audible Alarm
Two Audio Input 110 Terminal
Connections
Programmable Fault Contact Connection
EOL (4.7k Ohm) Fault Connection
Speaker Cable Connection: 8 Position 110
Terminals
Alarm Output Connection

Power Requirements

Operating Voltage 24 – 26 VDC
Current 100mA

System Supervision

Speaker Audio Output – DC loop terminated
with a V-9999 EOL unit.
All system faults are indicated by both an
audible and visual alarm. The audible alarm
may be silenced however the visual indicator
will continue to illuminate until the fault is
VL-9998RM, VL-9998WM
SUPERVISED IDF
1
repaired. The fault will "auto reset" after the
circuit is repaired.
If unit is configured for 2 page zones, it
appears as a single fault to the monitoring
system.

User Controls

Push button silence switch – Silences
local audible alarm only
Zone supervision by-pass jumper -
(Removes supervision from unused

outputs)

Program Jumpers – (Allows the unit to
provide supervision for 2 page zones – 6
speaker circuits each). Allows the unit to
have separate power for each group of 6
speaker circuits and allows the fault
contact to be N.O. (Open during Fault) or
N.C. (Closed during Fault).

Indicators

Power "ON" Green Led
Red Alarm Led for each output
Visual system main fault
Audible system fault with silence button

Inputs

One audio input for each zone of 6
speaker line connections.
Outputs
12 speaker line outputs divided into 2
zones six speaker lines each.
External alarm output (contact closure)

System Operation

The supervision module continuously monitors
the speaker runs for both opens or shorts and
provides both audible and visual indication of
wire faults. In the event of a speaker run wire
fault, the VL-9998 provides a red LED
indication identifying which speaker run has
the fault and sounds a local buzzer on the
panel for an audible alarm. A contact closure
Issue 2
947346

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VL-9998RM and is the answer not in the manual?

Questions and answers

Summary of Contents for Valcom VL-9998RM

  • Page 1 These instructions contain the specifications and guidelines necessary to install, operate, circuit is repaired. and maintain the VL-9998RM Rack Mount and VL-9998WM Wall Mount Supervised IDF. If unit is configured for 2 page zones, it appears as a single fault to the monitoring The VL-9998RM and VL-9998WM provide system.
  • Page 2 This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom Services L.L.C. be liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation, or use of the product.
  • Page 3 FIGURE 1: VL-9998RM SHOWING PROGRAMMING JUMPERS AND CONNECTIONS. (VL-9998WM IS SIMILAR) 947346...
  • Page 4 FIGURE 2: TYPICAL CONNECTIONS 947346...

This manual is also suitable for:

Vl-9998wm24vdc

Table of Contents