INTRODUCTION
The Ambient Level Controller (ALC) constantly monitors
room noise and adjusts the paging level to accommodate
for any changes in noise level. It has a built-in Sound
Pressure Level (SPL) meter.
SPECIFICATIONS
The ALC has two inputs, a loop start input (Telco) and a
balanced 600 Ohm line input. The Telco input shall have
priority over the line input. The microphone can be placed
up to 5000 feet from the ALC with shielded wire. The ALC
has five contact closure clock or remote control inputs. The ALC has four double throw relay outputs that
activate on the -6 dB and 0 dB levels.
The ALC adjusts page system level in 6 dB steps. The Telco input is loop start and has priority over the
line input. The line input has a dry contact closure which will provide an isolated dry contact closure at
the connections of the line output.
• Power consumption
• Frequency Response
• Signal to noise (dB ref.)
• Maximum output level
• Output relay activaltion points
• Output relay contact rating
• Number of relay output contacts
• Input level controls (internal)
• Control requirements
• Input types
• Output types
• Contact closure on output
• Contact closure controlled input
• Front panel controls
• Front panel indicators
• Maximum MIC line length
AMBIENT LEVEL CONTROLLER
V-5335621
250 Hz to 15 KHz + 2dB
0dB, -12dB with jumper installed
0dB and -6dB gain reduction
Dry contact closure
Line, Telco (loop start only)
Attenuation manual or automatic
Attenuation, automatic
Telephone input active
60 Watts
Better than -60dB
1 Amp
4
5
Line (600 Ohm)
Yes
Yes
Power
5000 feet
1
Issue 1
947194

Advertisement

loading

Summary of Contents for Valcom Pagepac Plus V-5335621

  • Page 1 ® PagePac Issue 1 AMBIENT LEVEL CONTROLLER V-5335621 INTRODUCTION The Ambient Level Controller (ALC) constantly monitors room noise and adjusts the paging level to accommodate for any changes in noise level. It has a built-in Sound Pressure Level (SPL) meter. SPECIFICATIONS The ALC has two inputs, a loop start input (Telco) and a balanced 600 Ohm line input.
  • Page 2: Technical Assistance

    When calling, have a VOM and a telephone test set available and call from the job site. Call (800) 782-5266 and ask for PagePac Technical Support, or call (540) 427-6000 for Valcom 24-hour Automated Support or visit our websites at http://www.pagepac.com and www.valcom.com.
  • Page 3: Installation

    INSTALLATION CAUTION: Use only the FM-14 Log Current Microphone. TELEPHONE standard microphone will be SYSTEM damaged if connected to the FM-15. PAGE PORT 600 OHM CONTACT FM-14 PAGE PORT CLOSURE INPUT NOTE: These terminals are redundant MIC input connections. Useful OUTPUT when a modular RJ-11 plug and 1/4 Modular...
  • Page 4 PBX HOST TELEPHONE SYSTEM PAGE UNIT FM-14 Set Zone to Contact PAGEPAC PLUS MICROPHONE Closure Output CONTROLLER NOTE: These terminals are redundant MIC input connections. Useful when a modular RJ-11 plug 1/4 Modular 0dbm 0dbu and cable is not available. Cord Full Modular...
  • Page 5: Telephone System

    CAUTION: Use only the FM-14 Log Current Microphone. standard microphone will be TELEPHONE damaged if connected to the FM-15. SYSTEM FM-14 Microphone These terminals are redundant NOTE: Dry Loop Start only. MIC input connections. Useful Do not apply when a modular RJ-11 plug and Ring Voltage or Dial Tone cable is not suitable.
  • Page 6 TELEPHONE SYSTEM CAUTION: Use only the FM-14 Log Current Microphone. A standard microphone will be damaged if connected to the FM-15. damaged if connected to the FM-15. PAGEPAC PLUS CONTROLLER FM-14 MICROPHONE These terminals are redundant MIC input connections. Useful when a modular RJ-11 plug and 1/4 Modular Zone...
  • Page 7 Power Input Line Out Line In Output T elco In Level 24 V olts AC Loop Start C1 G C1 C POWER SUPPLY AC 1.6A 60 HZ DO NOT DEFEAT THE SAFETY GROUNDING PIN ON THE POWER PLUG. USE ONLY THE POWER SUPPLY PROVIDED. Figure 5.
  • Page 8 The paging level meter [Red LED bar graph] (see Figure 7) indicates the paging level changes that are taking place with dual LEDs. Calibration complete. Clock Control or Remote Control of Levels Manual Override Clock Inputs or Remote Control Relay Outputs -24dB -24dB -18dB...
  • Page 9 FM-14 Log Current Microphone (see Figure 8) The wire for the FM-14 Log Current Microphone does not have to be shielded. This can be a phone line existing in the building. Use a RJ-11 connector at the microphone. When connecting the MIC, use a RJ-11 connector or wire directly to the terminal strip marked MIC ONLY.
  • Page 10: Top View

    Microprocessor Update Timing Period (see Figure 9) To change the microprocessor update period, remove the top cover, find the jumpers marked “Timing Adj. J4 and J5”, then refer to the chart below. PERIOD 0.5 Seconds 1.0 Seconds OUT 2.0 Seconds OUT 4.0 Seconds TIMING ADJ1 TIMING ADJ2...