Example) If you want to set as "MAIN: 3, CHANNEL: 1, RMC: B",
SEG1
SEG2
0
A
SEG7
SEG8
1
Assign option codes except SEG 1, 7 which are page options.
Setting the installation options in a batch
1
Make sure that the power is supplied to the indoor unit. If the indoor unit is not plugged in, it must include a power supply.
2
The panel (display) should be connected to an indoor unit to receive option.
3
Set the installation option according to the installation condition of an air conditioner.
The installation options of indoor units are set to like a below table by default.
Model
Installation option
Individual control of a remote controller(SEG20) is the function that controls an indoor unit individually when there
is more than one indoor unit.
No need to assign SEG3, 6, 9, 10, 16, 22, 23, 24 which are non applicable. Even though those segments are set, they
will be ignored.
If you set the applicable segments with numbers other than the indiciated, the initial setting will be maintained.
4
Set the indoor unit option by wireless remote controller.
SEG3
1
SEG9
-
1
AC018BNADCH
020010-100011-200000-300000
SEG4
SEG5
-
-
SEG10
SEG11
-
1
AC024BNADCH
020010-100041-200000-300000
SEG6
3
SEG12
B
English
23